Technical Data; Transportation And Storage - Güde GSE 5500 DSG Traduction Du Mode D'emploi D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
Operator Requirement
The operator shall read the instruction manual carefully before using the unit.
Qualification
No special qualification is required for use of the unit except for detailed direction by a professional.
Minimum Age
Only persons above 16 years of age are allowed to work with the unit.
Exempted from the provision is the use of the juvenile trainees if they work in the course of their
professional training with an aim to obtain the skill under trainer supervision.
Training
Use of the unit requires adequate lesson by a professional or the use of the manual only. Special training is
not required.

Technical Data

Max. output:
Permanent output:
Nominal voltage:
Nominal current:
Frequency /Protection type:
Engine design:
Volume:
Max. output:
Fuel/ tank volume:
Oil tank volume:
Running time ca:
Starting system:
Acoustic output level L
WA
Weight ca:
Dimensions L x W x H (mm):
Ordering No.:
AVR (automatic voltage control)
The voltage automatic control provides for the generator voltage spikes to be within the range of values
guaranteed by the power supplying company and not to expose the electronic instruments to any risk.
Caution:
Check before use of the appliance its usability for operation with the generator.
Producer (HIFI, PC, TV, Camcorder, etc.) needs to be asked in advance as far as
extremely sensitive electronics is concerned as the generator, due to the
combustion engine, does not produce constant sinusoidal voltage.

Transportation and Storage

Caution: The unit should be operated in the working position only (flat base) since the fuel or
oil could otherwise flow out and the lubrication is not guaranteed any more.
If the battery is employed, it should be taken out before any prolonged out-of-use period and stored at a
safe dry place (a heated area for example).
GSE 5500 DSG
230 V
4,4 kVA/3,5 kW
6,2 kVA/5,0 kW
4,0 kVA/3,2 kW
5,5 kVA/4,4 kW
230/400 V 1~
19 A 1 ~
50 Hz/IP 23
1-cylinder 4-stroke
418 ccm
7,35 kW/10 PS
oil /16 l
1,65 l
7,3 h (tank volume)
Electric starter
:
96 dB
185 kg
955 x 575 x 865
40586
400 V
16