ENGLISH
24
Technical Data
Electric generator
Art. No ...................................................................................................................................................................................................40728
Service connection ......................................................................... ....................................................................... 2 x 230 V ~ 50 Hz
Rated current ......................................................................................................................................................................................... 11 A
Constant power .................................................................................................................................................................. 2500 W
Rated power ................................................................................................................................... ..................................... 2800 W
Power class ................................................................................................................................................................................... G 1
Power factor ................................................................................................................................................................................0,85
Contents .............................................................................................................................................................................. 208 ccm
Engine type ............................................................................... ................................................................... 1-cylinder 4-stroke
Motor output .............................................................................................................................................................4 kW / 5,5 PS
Rated speed....................................................................................................................................................................3000 min
tank capacity (Petrol) ................................................................................................................................................................15 l
Consumption at half load ................................................................................................................................................ 1,25 l/h
Oil amount ....................................................................................................................................................................................0,6l
Weight ........................................................................................................................................................................................ 47 kg
Dimensions L x B x H ................................................................................................................................ 690 x 470 x 480 mm
Degree of protection ........................................................................................................................................................ IP 23 M
Noise and Vibration Information
Sound pressure level L
Uncertainty K = ................................................................................................................................................................................???? (A)
Measured sound power level L
Guaranteed sound power level L
Wear ear protectors!
Measured according to
stated in the service manual. Act responsibly toward
third parties.
The operator is responsible for accidents or risks to
third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Specified Conditions Of Use
This power unit has solely been designed for the
operation of electrical equipment with a maximum
power within the power unit performance data.
........................................................................................................................ ......................................???? (A)
PA
.............................................. .......................................................... ......................................???? (A)
1)
WA
.......................................... ...................................................................................................... ???? (A)
1)
WA
2000/14/EG
1)
Read and understand the operating instructions before using the appliance. Familiarise with
the control elements and how to use the appliance properly. Abide by all the safety measures
Higher starting current of induction appliances must
be considered.
The unit has been designed for operation of common
effective and induction appliances such as light
chains, electric hand tools (drills, electric chain saws,
compressors).
When connected to a stationary device such
as heating, electrical power, air conditioning
equipment or for the supply of mobile homes, it
is necessary to contact a professional electrician
and heating manufacturer as far as connection
and grounding is concerned.
Not observing general regulations in force and
instructions from this manual does not make the
manufacturer liable for damages.
Protective equipment „Protective separation with
potential balancing" is provided and integrated by
the producer.
Connection, installation and
operation
AVR
Automatic voltage control makes sure the
GSE 3701 RS
-1