––– STEP 10 –––
10.1 - ADVANCED ADJUSTMENTS
10.1.1 - Parameter adjustment using radio transmitter
Using the radio transmitter you can adjust certain operating parameters
on the control unit: there are eight parameters (Table 9):
1) Pause time: duration for which the leaves remain open (in the case of
automatic closure).
2) Pedestrian opening: pedestrian opening mode of the leaves.
3) Motor force: maximum force above which the control unit detects an
obstacle, and reverses the movement.
Parameters
N°
Value
1°
10s
2°
20s (*)
Pause time
3°
40s
4°
80s
1°
Open 1 leaf halfway
Pedestrian
2°
Fully open 1 leaf (*)
opening
3°
2 leaves partially opened to 1/4 of the full course
4°
2 leaves partially opened to half of the full course
1°
Low
2°
Medium low (*)
Motor force
3°
Medium high
4°
High
1°
"Open", "Stop", "Close", "Stop"
"OPEN"
2°
"Open", "Stop", "Close", "Open" (*)
function
3°
"Open", "Close", "Open", "Close"
4°
Open only
(*) Original factory value
Parameters
N°
Value
1°
No discharge (*)
2°
0.1s (Minimum)
3°
Discharge on close
4°
Motor 1
5°
0.4s (Medium)
6°
7°
8°
0.7s (Maximum)
1°
No discharge (*)
2°
0.1s (Minimum)
3°
Discharge on open
4°
Motor 1
5°
0.4s (Medium)
6°
7°
8°
0.7s (Maximum)
1°
No discharge (*)
2°
0.1s (Minimum)
3°
4°
Discharge on close
Motor 2
5°
0.4s (Medium)
6°
7°
8°
0.7s (Maximum)
1°
No discharge (*)
2°
0.1s (Minimum)
3°
4°
Discharge on open
Motor 2
5°
0.4s (Medium)
6°
7°
8°
0.7s (Maximum)
(*) Original factory value
FURTHER DETAILS
4) "OPEN" function: sequence of movements associated to each "OPEN"
command.
5) Discharging Motor 1 when closing: adjusts the length of the "brief
reverse" of the motor after execution of the Close manoeuvre, in order
to reduce the final residual force.
6) Discharging motor 1 when opening: adjusts the length of the "brief
reverse" of the motor after execution of the opening manoeuvre, in
order to reduce the final residual force.
7) Discharging motor 2 when closing: adjusts the length of the "brief
reverse" of the motor after execution of the Close manoeuvre, in order
to reduce the final residual force.
8) Discharging motor 2 when opening: adjusts the length of the "brief
reverse" of the motor after execution of the opening manoeuvre, in
order to reduce the final residual force.
TABLE 9
Action: operation to be carried out at step 3 in the adjustment phase
Press T1 once
Press T1 twice
Press T1 three times
Press T1 four times
Press T2 once
Press T2 twice
Press T2 three times
Press T2 four times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
TABLE 10
Action to perform
Press T1 once
Press T1 twice
Press T1 three times
Press T1 four times
Press T1 five times
Press T1 six times
Press T1 seven times
Press T1 eight times
Press T2 once
Press T2 twice
Press T2 three times
Press T2 four times
Press T2 five times
Press T2 six times
Press T2 seven times
Press T2 eight times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T3 five times
Press T3 six times
Press T3 seven times
Press T3 eight times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
Press T4 five times
Press T4 six times
Press T4 seven times
Press T4 eight times
English – 19