P1 LED
Off
1 fast red flash each second
1 fast green flash each sec-
ond
2 fast green flashes + pause
for 1 second
1 fast red flash followed by 1
fast green flash + 1 second
pause
1 fast green flash followed by
1 fast red flash + 1 second
pause
2 fast red flashes + pause for
1 second
Red LED on
Red LED on
1 red coloured short flash
every 0.5 seconds
1 green coloured short flash
every 0.5 seconds
1 red+green coloured short
flash every 0.5 seconds
P2 LED
Off *
On
Series of quick flashes, from
1 to 4
5 quick flashes
1 slow flash
28 – English
Status
Fault or control unit in standby state
The control unit has no memorised wireless
devices configuration (factory condition)
Automation moving or in test: The control unit
has at least one accessory device installed.
The automation is neither moving nor in test.
The control unit has at least one accessory
device installed; the last manoeuvre was suc-
cessful and all devices respond correctly and
have their batteries charged
The automation is neither moving nor in test.
The control unit has at least one accessory
device installed; the last manoeuvre was suc-
cessful and all devices respond correctly but
at least one has a battery which is nearly
empty.
The automation is neither moving nor in test.
The control unit has at least one accessory
device installed; the last manoeuvre was suc-
cessful and all devices respond correctly the
control unit did not receive a good radio
signal from one of them.
The automation is neither moving nor in test.
The control unit has at least one accessory
device installed; the last manoeuvre was suc-
cessful and all devices respond correctly but
at least one device has a battery which is
nearly empty and at least one device from
which the control unit did not receive a
good radio signal.
The automation is neither moving nor in test. The
control unit has at least one accessory device
installed; the last manoeuvre was successful and
all devices respond correctly but at least one
device on the network did not respond.
The automation is moving or in test. The con-
trol unit has at least one pair of photocells
installed.
Network learning procedure by new (cloning)
in course; the control unit is waiting for the
address of the old network
The control unit is detecting the old devices
Network learning procedure by new (cloning)
in course; the control unit has received the
address of the old network
Status
All OK
Memorisation in Mode 1
Memorisation in Mode 2
Cancellation OK
Wrong command
Action
Automation could be in standby; Press any key to see if the led
lights up or flashes; if this causes no effect make sure there is
power supply; check that the fuses are not blown; if this is the
case, verify the cause of the fault and then replace them with
others of the same value
Normal operation; the control unit does not have any wireless
device installed and is ready to learn a wireless network
Normal operation
Normal operation
Check the battery charge level on the wireless devices; activate
the test procedure (paragraph 8.2 )
Limited radio communication; if possible, search for a better
position for the device
Check the battery charge level on the wireless devices; activate
the test procedure (paragraph 8.2 ).
Limited radio communication; if possible, search for a better
position for the device
Check the battery charge level on the wireless devices; activate
the test procedure (paragraph 8.2 ).
Limited radio communication; if possible, search for a better
position for the device
Normal operation if there is an obstacle between at least one
pair of photocells, or at least one photocell is not responding.
Check the battery charge level on the wireless devices; activate
the test procedure (paragraph 8.2 ). It is possible that radio com-
munication is at its limit; if possible, search for a better position
for the device. There may also be a radio interference problem
Normal operation
Normal operation
Normal operation
Action
No memorisation in progress.
During memorisation in mode 1, it is normal for it to take a maxi-
mum of 10 s.
During memorisation in mode 2, it is normal for it to take a maxi-
mum of 10 s.
Completion of deletion of a transmitter
A command has been received from an unmemorised transmit-
ter