CHECKING FOR BLOCKAGES
WARNING: To reduce
the risk of shock and
unintended operation,
turn power off and
unplug unit before
servicing.
TIP: You can also check
for blockages in the hose
and tubes. Just remove
floor nozzle, dust cup and
hose and shine a flashlight
in the openings.
19
1-800-798-7398
STEP 1
STEP 2
BOTTOM OF FLOOR NOZZLE
Use a coin to unlock the
1
two locks on the bottom of
the floor nozzle.
2 Lift tabs and pull up to
expose the airway. Tilt
nozzle neck back to
straighten air way. Shine a
flashlight from the bottom to
check for possible blockage
in the airway.
STEP 3
3 Remove any string, carpet
fibers or hair that may
be wrapped around the
brushroll. There is a groove
along the brush bar that
allows a pair of scissors to
cut across it to loosen up
the debris. To close, push
down until you hear it click
into place then lock the two
locks.