Introduction; Safety Instructions; Using The Correct Cable Connector; Improper Use Of The Welding And Power Supply Cables - Rothenberger ROWELD ROFUSE Basic 48 Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1

Introduction

Dear Customer:
Thank you very much for purchasing our product. We are confident that it will meet your expectations.
£
The ROWELD
ROFUSE Basic 48 is designed exclusively for welding electrofusion fittings made of plas-
tic. Additionally, it records data on the welding process, including user inputs, and saves them to a weld-
ing report that can be printed or downloaded to a PC for further processing.
£
The ROWELD
ROFUSE Basic 48 was manufactured and checked according to state-of-the-art technol-
ogy and widely recognized safety regulations and is equipped with the appropriate safety features.
Before shipment, it was checked for operation reliability and safety. In the event of errors of handling or
misuse, however, the following may be exposed to hazards:
x
the operator's health,
®
x
the ROWELD
ROFUSE Basic 48 and other hardware of the operator,
x
the efficient work of the ROWELD
All persons involved in the installation, operation, maintenance, and service of the ROWELD
Basic 48 have to
x
be properly qualified,
x
operate the ROWELD
x
read carefully and conform to the User's Manual before working with the welding unit.
Thank you.
2

Safety Instructions

2.1

Using the Correct Cable Connector

Use the appropriate cable connectors that are compatible with the fitting type used. Be sure the contact is
firmly established and do not use burnt cable connectors or connection adapters or such that are not de-
signed for the intended use.
2.2

Improper Use of the Welding and Power Supply Cables

Do not carry the ROWELD
the socket. Protect cord and cables from heat, oil, and cutting edges.
2.3

Securing the Fitting and the Joint

Use clamps or a vice to secure the fitting and the joint before welding. The fitting manufacturer's installa-
tion instructions, DVGW, DVS, European and national regulations will have to be respected in all cases.
The welding procedure must never be repeated on the same fitting, since this may cause parts under
power to be accessible to the touch.
2.4

Tool Maintenance

Keep your tools clean to ensure proper and safe work. Respect the indications and instructions about
their maintenance.
Check adaptors, plugs, and cables regularly and have them replaced by an authorized specialized ser-
vice shop if they are damaged. Keep the connection adapters free from oil, grease, and dirt.
£
ROFUSE Basic 48.
£
ROFUSE Basic 48 only when observed,
£
ROFUSE Basic 48 by its cord and do not pull the cord to unplug the unit from
£
ROFUSE