Robert Juliat 1011+ Manuel D'utilisation page 47

Masquer les pouces Voir aussi pour 1011+:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.3. The off command is given, but the lamp
stays on.
Green &
red LED :
off
Green &
red LED
on.
4 . NON-FUNCTIONING DIAGNOSIS FOR THE SHUTTER :
1.1 The shutter command is given, but no
action.
1.2 . The shutter only excepts an up command,
does not except an down command.
1.3 . The shutter reacts badly, and the motor
runs continuous.
1.4. The shutter act in a saw-tooth movement
on a fluent command.
1.5. Shutter action is delayed to command.
47
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
1200W HMI FOLLOW SPOT
message unchanged.
message unchanged.
New shutter level
not displayed.
New shutter level
displayed.
The shutter does
not react or reacts
badly.
The shutter level is
correctly displayed.
Transmission Data error :
connection failure : check the wiring.
( refer to Tech. File p. 12 & 24 ).
connection damaged or :
( refer to Tech. File p. 12 & 24 ).
Command link error :
Digital - refer to 3.1.
Analog - refer to 2.
Shutter cable demaged :
Check cable.
Faulty power supply :
Change CAD :
( Refer to Tech. File - page 40 )
Motor demaged : Change the
whole shutter unit.
( refer to Tech. File - page 32 )
Error on the Shutter unit :
Change the whole shutter unit.
( refer to Tech. File - page 32 )
1011+B
VALID SINCE : 20.10.03
Resend the
"LAMP OFF"
command.
Resend the
"LAMP OFF"
command.
resend the
resend the
level
level
command.
command.
resend the
level
command.
resend the
level
command.
resend the
level
command.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1011+b1011+c

Table des Matières