PUTTING THE LAMP INTO PLACE.
User's precautions:
- Disconnect from the mains.
- Lamp is cold.
- Avoid touching the bulb of the lamp.
- Open the bonnet and the side covers of the lantern.
- Use only when lamp is in place
Preparation of the lamp:
- Unscrew the nuts 1 without completely taking them off.
Putting the lamp into place :
- Place the lamp into the contacts 2 ,
the tip-off upwards and toward the back D .
- Tighten the nuts 1 firmly, by hand.
Warning : A badly tighten lamp can cause
a bad contact and a defective
ignition. Check regularly that the
nuts 1 are well tightened.
Lamp.
Warning : Do not use a lamp, if the diameter
of the bulb is greater than Ø28mm.
SWITCHING ON - ref.: 1011+ & 1011+C only.
Warning :
Carry out the connections before
connecting to the mains ( refer to page 10).
- No matter what the position of the circuit breaker 3 , make sure
that the mains checklight 4 is ON.
- Engage the circuit breaker 3 and the automatic breaker 5 .
Control mode choice - 2 possibilities are offered:
1 - the "ON / OFF" switch 6 .
2 - an external switch on relay contact (1A - 250V), connected
between two points on the connector 7 .
! IMPORTANT :
The priority between 6 and 7 is always the ignition - switching OFF
is only possible if 6 and 7 are in the OFF position.
14
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
1200W HMI FOLLOW SPOT
Disconnect from the mains before any servicing.
Service only by qualified technician.
1
D
1011+, 1011+B &
1011+C
VALID SINCE : 20.10.03
A
B
C
2
B
C
1
A
Ø28 maxi
180
D
E
2
E