Mains voltage.
- Check the conformity of the power supply unit.
Rating plate 11 : Lamp power.
Lighting unit / Power supply connection.
- Connect the Lighting unit/Power supply cable C by passing it
inside the yoke.
- Leave a little slack and then block the cable C into the lock d .
- Place the lamp into position - refer to page 14.
- Connect the cable 2 to the mains.
CAUTION - For your security !
- Never open the lantern's bonnet when the
lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when lamp in place.
10
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
1200W HMI FOLLOW SPOT
d
TECHNICAL FILE
DESCRIPTION.
+
A
1011
e - EM HARTING 16 x 16A power socket.
f - 10A. EEC - Female mains socket.
B
Power supply unit.
1 - EF HARTING 16 x 16A - 2 latch connector.
2 - Mains cable.
3 - Time meter.
4 - General 16A circuit breaker (208/245V).
- General 25A circuit breaker (110V).
5 - Mains, checklight.
6 - 1A automatic breaker.
7 - "ON/OFF" switch.
8 - "Wieland" 2 point connector : remote control.
9 - Lamp ON, checklight.
If the lamp's checklight is OFF when the switch is in
the ON position; the lighting of the lamp has failed.
Repeat the operation - refer to page 14.
10 & 11 - Rating plate.
C
Lamp cable.
Cable H07 RN-F 19G 1,5mm
with 16 x 16A M/F HARTING connectors.
1011+ & 1011+C
VALID SINCE : 20.10.03
B
3
30.23
7
5
AMONT
ON
OFF
6
MAINS
FUSE
4
TELECOMMANDE /
REMOTE CONTROL
0 - OFF
0 - OFF
0 - OFF
2
220/240V 50Hz
Power supply unit
(P.S.U.)
Manual shutter version.
length 3m fitted
2
8
9
LAMP ON
1
10
HMI 1200
11