Robert Juliat 1011+ Manuel D'utilisation page 43

Masquer les pouces Voir aussi pour 1011+:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1.2. Untimely extinction of the lamp.
2. USING THE " ANALOG " MODE
2.1. The ballast and the CAD are on ;
the" lamp on" command is given,
but the lamp does not switch on.
2.2. Intimely extinction of the lamp.
43
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
1200W HMI FOLLOW SPOT
message displayed :
LAMP OFF
CHECK SECURITY
message unchanged.
message unchanged.
message displayed :
RJ LAMP LIGHTING
TRY FAILURE
message displayed :
LAMP FAILURE
CHECK SECURITY
message unchanged.
Message in
start-up display :
" RJ LAMP OFF "
Return to 1.1 and follow the
procedure.
Network transient failure : give the
off command, or switch off
the mains for 30 sec.
Check the analog command cable :
the command has not been
recieved.
( refer to Tech. File p. 12 & 24 )
Return to 1.1 and follow the
procedure.
Return to 1.1 and follow the
procedure.
Network transient failure : give the
off command, or switch off
the mains for 30 sec.
Command signal failure :
check the cable
( refer to Tech. File p. 12 & 24 )
1011+B
VALID SINCE : 20.10.03
Restart the
"LAMP ON"
procedure.
Restart the
"LAMP ON"
procedure.
Restart the
"LAMP ON"
procedure.
Restart the
"LAMP ON"
procedure.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1011+b1011+c

Table des Matières