CONNECTIONS.
Mains voltage.
- Check the conformity of the power supply unit.
Rating plate 10 : Lamp power.
Lighting unit / Power supply connection.
- Connect the lamp cable
P.S.U. and connector e
- Connect the cable
D
to the connector ( d ) of the
ballast and to the connector
- Place the lamp into position - refer to page 14.
- Connect the DATA line on connector ( a ) "XLR5" or
the analog command to the the connector ( c ) "XLR4".
( For the connection configurations : refer to page 24 ).
- Connect the optional units that are possible, to connector f
( Only DATA ).
- Plug the cable
8
to the mains. If the power is present, the
checklight 1
lights up immediately.
- Engage the automatic breaker 3 and check that the CAD 900
protection 4
is well engaged.
- Engage the automatic breaker 2 .
- Lock the cable C into the cable lock
WARNING !
- Never open the lantern's bonnet when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when lamp is in place.
12
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
1200W HMI FOLLOW SPOT
A
e
f
i
C to the connector
7 of the
to the lighting unit.
g of the lighting unit "XLR7".
i .
TECHNICAL FILE
g
h
E
B
C
DESCRIPTION.
+
A
1011
B - Motorized shutter with CAD.
e - EM HARTING 16 x 16A power socket.
f - 10A. EEC - Female mains socket.
g - EM XLR7 shutter + DATA.
h - EF XLR5 output DATA.
B Power supply unit.
1 - Mains checklight.
2 - 6A automatic breaker.
3 - General 16A automatic breaker (208/245V).
4 - 1A automatic breaker.
6 - Ventilation opening
7 - EF HARTING 16 x 16A - 2 latch connector.
8 - Mains cable 3G x 1,5 mm
9 - CAD 900 local controls.
10 - Rating plate.
11 - Power supply selector :
208V. 60Hz, 230V. 50Hz & 245V. 50Hz.
Position locked by a screw.
C Lamp cable.
Cable H07 RN-F 19G1,5 mm
with 16 x 16A M/F HARTING connectors.
D Shutter cable.
14 conductors reinforced shielded cable - length 3m
fitted with XLR7 M/F connector.
E
Analog control fader cable.
14 conductors reinforced shielded cable - length 3m
fitted with XLR4 M/F connector.
1011+B
VALID SINCE : 20.10.03
D
Power supply unit
(P.S.U.)
DATA
DMX 512 Line.
DATA Line.
(DON'T OBSTRUCT THE AIR GAPS).
2
(2,5m) + 10/16A. male plug.
2
length 3m fitted

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1011+b1011+c

Table des Matières