Reflector, Aspheric Lens And Spark-Gap - Robert Juliat 1011+ Manuel D'utilisation

Masquer les pouces Voir aussi pour 1011+:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Disconnect from the mains before any servicing.
Service only by qualified technician.
REFLECTOR.
- Disconnect from the mains.
- Open the bonnet and the side covers of the lantern.
- Take out the lamp.
( Refer to the page 14 ).
- Unscrew the 2 screws 1 .
- Withdraw the reflector holder set 2 .
- Clean the reflector 3 with a soft dry cloth.
ASPHERIC LENS.
- Unscrew the 2 screws 4 .
- Withdraw the lens holder set 5 .
- Clean the lens 6 with a soft dry cloth.
- Remount all the parts.
- Clean in the same way, the lenses in the zoom.
SPARK-GAP.
- Disconnect from the mains.
- Open the lantern's bonnet.
- Unscrew the nut a , while holding in place the counter-nut b
.
- Then, unscrew the counter-nut b .
- Adjust, with a 2,5 Allen key, the upper electrode c to
1 mm from the electrode.
- Tighten the counter-nut b and the nut a .
• The adjustment is made, when manufactured.
Interfere only in case of a faulty starting.
20
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
1200W HMI FOLLOW SPOT
1011+, 1011+B &
1011+C
VALID SINCE : 20.10.03
6
4
1
5
2
3
2,5
b
8
1 mm
4
1
a
8
c

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1011+b1011+c

Table des Matières