Ignition Time Delay - 1011+ & Changing The Iris Cassette - Robert Juliat 1011+ Manuel D'utilisation

Masquer les pouces Voir aussi pour 1011+:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IGNITION'S TIME-DELAY - ref.: 1011
The adjustment is effectuated at the factory;
Ignition's time-delay : 5/10 of a second ±20%.
! ATTENTION.
- It is inadvisable to adjust the time-delay without
consulting beforehand our technical services.
- The circuit board's power is NOT isolated from
the 230V network.
- Service only by qualified technician.
CHANGING THE IRIS CASSETTE.
- Unscrew the screws 1 .
- Remove the metal plates 2 .
- Remove the iris cassette 3 .
- Mount the new iris cassette into place.
- Remount the metal plates 2 .
- Rescrew the screws 1 .
GOBOS CHANGER SETTING.
NOTE.
Before adjusting, put a drop of breaking fluid onto the threads
of the setting screws.
22
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
1200W HMI FOLLOW SPOT
+
only.
Lamp ON, checklight
1011+, 1011+B &
1011+C
VALID SINCE : 20.10.03
Time-delay circuit.
(found inside the power
supply unit, see page 37).
Always adjust to
0,54 sec. (in a anti-
clockwise direction).
Setting screws for gobo changer.
INSIDE THE ZOOM.
Adjusting stopper for positioning.
0,54 sec.
1
2
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1011+b1011+c

Table des Matières