* If you use alkaline detergents, thoroughly rinse after washing.
* Do not spray with direct jets of water or with high-pressure equipment since any water getting into the
outer casing can jeopardize the safety of the machine.
* Clean the condenser at least every six months with a soft brush or with a vacuum cleaner.
When the appliance has not to be used for long periods, disconnect the electrical power supply, spread a
protective film all over the stainless steel surfaces by passing over them a cloth soaked in Vaseline oil,
and air the rooms periodically
7.2 Special maintenance
The special maintenance procedures should be carried out by qualified and authorized personnel,
possibly by means of the technical service of the manufacturer of the component requiring servicing.
CAUTION: it is recommended to use only genuine spare parts, in compliance with the same technical
specifications as the ones replaced. CAUTION: in any case, before starting, the electrical power supply
must be disconnected by deactivating the automatic switch located up-line from the appliance.
7.2.6 Replacing the power supply cable
To replace the power supply cable it is necessary to carry out the following operations:
1. Make sure you have disconnected the electrical power supply.
2. Remove the upper cover by drawing it upwards and paying attention to the electric cables.
3. Disconnect the two power cables from the switch and the earth lead (yellow-green) from the
equipotential screw, loosen the external nut and remove the power cable. In its place insert the new one,
making it pass through the hole on the instrument panel and connecting it like the one just removed.
4. Put the upper cover back into its original position.
FIG. 1