GB
Defrosting, cleaning and maintenance
Automatic defrosting.
The appliance is defrosted automatically.
Defrost water runs through a pipe and is
collected in a tray above the compressor
where the heat generated by the compres-
sor causes it to evaporate.
Cleaning.
Switch off the appliance by pressing the on/
off button before cleaning it inside.
The cabinet is best cleaned using warm wa-
ter (max. 65°C) with a little mild detergent.
Never use cleaning agents that scour. Use
a soft cloth. Rinse with clean water and dry
thoroughly. It is important to prevent water
from entering the control panel.
The defrost water channel, in which
condensation from the evaporator runs, is
located on the rear wall of the cabinet and
must be kept clean. Add a few drops of dis-
infectant, e.g. Rodalon, to the defrost water
drain a couple of times a year, and clean
the drain using a pipe cleaner or similar.
Never use sharp or pointed implements.
The sealing strip around the door must be
cleaned regularly to prevent discolouration
and prolong service life. Use clean water.
After cleaning the sealing strip, check that it
continues to provide a tight seal.
Dust collecting on the compressor and
in the compressor compartment is best
removed using a vacuum cleaner.
11