DBI SALA 2100180 Mode D'emploi page 7

Dispositif d'ancrage à contrepoids de toiture
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
4.3
If inspection reveals an unsafe or defective condition, remove the unit from service and destroy, or contact DBI-SALA for
possible repair.
4.4
USER EQUIPMENT: Inspect each system component or subsystem (i.e. SRL, full body harness, lanyard, lifeline, etc.)
per associated manufacturer's instructions. Refer to manufacturer's instruction supplied with each system component for
inspection procedures.
5.0
mAINteNANCe, seRVICe, stoRAGe
5.1
The Roof Top Counterweight Anchor System components require no scheduled maintenance, other than repair or
replacement of items found defective during inspection. See Section 4.0. If components become heavily soiled with
grease, paint, or other substances, clean with appropriate cleaning solutions. Do not use caustic chemicals that could
damage system components.
6.0
speCIFICAtIoNs
6.1
MATERIALS:
Base Weight: Rubber coated cast iron
Counterweights: Galvanized cast iron
L-bolts: Steel
6.2
WEIGHT:
Each Counterweight: 45 lbs.
7.0
lAbelING
7.1
This label must be present on the Anchor and fully legible (item 2 in Figure 1):
7

Publicité

Table des Matières
loading

Table des Matières