Mitsubishi Electric CITY MULTI PUHY-P-YSMF-B Manuel D'installation page 41

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2 Diagnostic switch (SW1) and the service LED on multi-controller board of the variable capacity unit can be used to judge a malfunction
of outdoor unit.
<Operation of self-diagnosis switch (SW1) and the service LED display>
Self-diagnosing
SW1 setting
item
Relay output
display 1
A
(Lighting)
B
1 2 3 4 5 6 7 8 9 10
Check
C
a
display 1
(Blinking)
A
Relay output
B
display 2
1 2 3 4 5 6 7 8 9 10
A
B
1 2 3 4 5 6 7 8 9 10
A
B
1 2 3 4 5 6 7 8 9 10
Check
indoor unit
A
B
1 2 3 4 5 6 7 8 9 10
A
B
1 2 3 4 5 6 7 8 9 10
A
B
1 2 3 4 5 6 7 8 9 10
A
B
1 2 3 4 5 6 7 8 9 10
Indoor unit
b
mode
A
B
1 2 3 4 5 6 7 8 9 10
A
B
1 2 3 4 5 6 7 8 9 10
A
B
1 2 3 4 5 6 7 8 9 10
A
B
1 2 3 4 5 6 7 8 9 10
Indoor unit
thermostat
A
B
1 2 3 4 5 6 7 8 9 10
A
B
1 2 3 4 5 6 7 8 9 10
A
Indoor unit
B
address
1 2 3 4 5 6 7 8 9 10
a Outdoor unit
b Indoor unit
A ON
B OFF
Display at LED lighting (blinking)
Flag 1
Flag 2
Flag 3
During
Compres-
Compres-
compres-
sor 1
sor 2
sor run
operations
operations
0000 to 9999 (Alternate display of address and error code)
SV4
21S4b
SV5b
No.1
No.2
No.3
unit
unit
unit
No.9
No.10
No.11
unit
unit
unit
No.17
No.18
No.19
unit
unit
unit
No.25
No.26
No.27
unit
unit
unit
No.1
No.2
No.3
unit
unit
unit
No.9
No.10
No.11
unit
unit
unit
No.17
No.18
No.19
unit
unit
unit
No.25
No.26
No.27
unit
unit
unit
No.1
No.2
No.3
unit
unit
unit
No.9
No.10
No.11
unit
unit
unit
No.17
No.18
No.19
unit
unit
unit
No.25
No.26
No.27
unit
unit
unit
Displays in order the addresses (1 through 50) of all indoor units connected to the outdoor unit.
* Turn SW4-2 of variable capacity unit off. If SW4-2 is on, constant capacity unit data will be
displayed.
C At factory shipment
Flag 4
Flag 5
Flag 6
Flag 7
SV22/32
21S4
SV1
SV6
CH2, 3
52F
No.4
No.5
No.6
No.7
unit
unit
unit
No.12
No.13
No.14
No.15
unit
unit
unit
No.20
No.21
No.22
No.23
unit
unit
unit
No.28
No.29
No.30
No.31
unit
unit
unit
No.4
No.5
No.6
No.7
unit
unit
unit
No.12
No.13
No.14
No.15
unit
unit
unit
No.20
No.21
No.22
No.23
unit
unit
unit
No.28
No.29
No.30
No.31
unit
unit
unit
No.4
No.5
No.6
No.7
unit
unit
unit
No.12
No.13
No.14
No.15
unit
unit
unit
No.20
No.21
No.22
No.23
unit
unit
unit
No.28
No.29
No.30
No.31
unit
unit
unit
remarks
Flag 8
Flag 8 always lights
Always
at microcomputer
lighting
power ON
21S4b and SV5b
are closed with flag 1
No.8
unit
unit
No.16
unit
unit
Lights at emergency
stop in IC
Turns off by resetting
No.24
unit
unit
No.32
unit
unit
No.8
unit
unit
No.16
unit
unit
Lights at cooling
Blinks at heating
Turns off at stop/fan
No.24
unit
unit
No.32
unit
unit
No.8
unit
unit
No.16
unit
unit
Lights at thermostat
on Turns off at
thermostat off
No.24
unit
unit
No.32
unit
unit
41

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

City multi puhy-ysmf-b

Table des Matières