Télécharger Imprimer la page

Güde 300/10/50 N Mode D'emploi page 14

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
After each use
clean the air holes and mobile parts off dust.
Regularly
paint metal parts w ith oil (universal oil)
check w hether all screw s are tightened.
Regularly (once a month at least) release the condensed
fluid from the air jet; failing to observe this regulation may
lead to guarantee for rusting through expiry – apart from
that, the compressor is maintenance-free.
(The condensed fluid may be brow n-coloured due to
surface layer from the air jet)
1.
Pull the connector plug out of socket!
2.
At low pressure in the air jet open the bleeder (9)
(max. of 1 bar) and completely empty the condensed
fluid (use a suitable container)
Fault
A
Compressor does not start
after switching on
Compressor shortly starts or
B
buzzes at the reach of the
sw itch-on pressure and then
sw itches off automatically
C
Compressor runs w ithout stop
D
In operation the relief valve
under the pressure switch
releases the pressurized air
After switch-off pressure is
E
reached the relief valve under
the pressure switch releases the
pressurized air until the sw itch-
on pressure is reached
F
Compressor sw itches on
frequently
Safety valve blows off
G
Compressor heats too much
H
Cause
Pressure in the air receiver is higher than sw itch-
on pressure
Faulty feeding
Circuit breaker of the motor interrupts the pow er
feed
Faulty pressure switch
Electric cable is longer than permitted or is of too
small cross-section
Suction filter is contaminated heavily
Pneumatic tool has too high air consumption
Leak at the compressor
Too much condensing w ater in air receiver
Leaky pneumatic piping
Mud-discharge valve is open or missing
Leaky relief valve
Insert of the non-return valve is leaky or
faulty
Non-return valve is damaged
Too much condensation water in the air
receiver
Compressor is overloaded
Pressure in the air receiver is higher than set-up
sw itch-off pressure
Safety valve is faulty
Intake air is insufficient
Cooling ribs at the cylinder (cylinder head) are
dirty
Too long period of use
3.
Close the valve.
Air filter
Sometimes it is necessary to clean the filter bed. For that purpose
remove the air filter cover screw and remove the foam filter. Wash
it in w arm soap w ater solution. Let the foam filter dry and reinsert
it to its place. Now assemble the air filter cover again.
Fuse against overheating: (depending on model)
If the compressor is loaded by a technical defect or possibly also
by continuing operation, the pow er feed w ill be automatically
interrupted by a thermo-sw itch. If such situation occurs it is
advisable to disconnect the compressor from the mains and let it
cooled dow n for approx. 5 minutes. If the compressor does not
start after certain period of operation, let it cooled dow n for
additional 3 minutes.
Rem edy
Release the pressure from the air receiver so
that the pressure switch switches automatically
Have the power feeding checked by an
authorized person
Have the pressure switch replaced by an
authorized person
Check the length and cross-section of
the electric cable
Clean or replace the suction filter
Check the air consumption of the pneumatic
tool; contact authorized reseller
Locate the leak, notify Güde service
Drain the condensing water
Check the pneumatic piping, seal the leak
Cl o se or i n sert i t
Clean or replace the relief valve
Clean or replace the insert of the non-return
valve
Repl a ce the non-return val v e
Drain the condensation water
Have the pressure switch readjusted
/replaced by an authorized person (Güde
Service)
Replace the safety valve or contact Güde
Service
Make sure that sufficient intake and outlet of
the air is guaranteed (minimum distance from
a w all 40 cm)
Clean the cooling ribs at the cylinder (cylinder
head)
Sw itch off the compressor
14

Publicité

loading

Ce manuel est également adapté pour:

50054