Page 18
ENGLISH
1.
Be sure pool pump is turned off.
2.
Install the flow/temp/salinity sensor into the vessel
(see Figure 9).
3.
Install the strain relief provided with the vessel
kit into the low voltage knock out at the power
pack. Feed the connector end of the flow/temp/
salinity sensor cable through the DC cord strain
relief fitting. Be certain the connector is clean
and dry, then plug the cable into the connector on
the power center printed circuit board as shown
in Figures 10, 11 and 12. (Do not pull flow/temp/
salinity sensor cable too tight, allow some slack).
4.
Plug the DC cord into the cell stud terminals
protruding from the cell top at the Nature
Soft vessel. The DC cord can be plugged into the
cell in either direction.
5.
Connect the DC cord to the power center. Feed
the DC cord through the same strain relief fitting
as the flow/temp/salinity sensor at the power
pack. Plug the DC cord into the two (2) spade
connectors of the wiring harness located in the
low voltage raceway of the control/power center,
see Figures 10, 11 and 12. This wiring harness
establishes the connection between the cell and the
power interface board.
Figure 9.
Vessel Installation and Flow/Temp/Salinity Sensor
|
Zodiac
Nature
Fusion Soft
Installation and Operation Manual
®
2®
To avoid risk of damage to the equipment and
possible injury, it is important to make sure the DC
cable connector is fully seated on the cell electrolytic
stud terminals.
6.
Tighten strain relief fitting screws for the flow/
temp/salinity sensor and the DC cord. Do not pull
flow/temp/salinity sensor cable or DC cord too
tight. Allow some slack cable inside of power
pack enclosure.
7.
Prior to reattaching the front cover, check the
wiring. Be sure the flow/temp/salinity sensor is
plugged in. The DC cord should be plugged in.
Fusion
2
Also, check the AC wiring.
8.
If the ribbon cable connecting the user interface to
the power interface board was disconnected during
installation then reconnect before reattaching
cover (see Figures 10, 11 and 12).
Do not operate the electrolytic cell without water
circulation. A buildup of flammable gases will result in
FIRE or EXPLOSION.
Flow/Temp/Salinity Sensor Face must
be clean at all times for proper operation
CAUTION
WARNING
Sometimes
Salinity
Not Covered
Studs
Temperature
Sensors