It's possible to read the water temperature: when water is flowing through the heat pump, press on
flashes for 10 seconds then displays the fixed requested temperature.
It's possible to lock the keyboard:
- lock the keyboard: press on
then:
.
- unlock the keyboard: press on
.
3.4 Checks to perform after operating the appliance
After following the steps for running the heat pump, temporarily cut the water circulation to check that the heat
pump stops operating:
3.5 Winterizing
Winterizing is essential due to the risk of the condenser freezing. This situation is not covered by the
warranty.
To avoid damaging the appliance with condensation, do not cover it with an air‐tight cover.
switch off the heat pump by pressing the
ensure that no water is flowing through the heat pump,
drain the water condenser (risk of freezing) by removing the two pool water inlet and outlet connections at
the back of the heat pump,
in the case of a full winterizing of the pool: connect the inlet and outlet connections "lightly" without
tightening (one turn) in order to avoid foreign bodies entering into the condenser,
in the case of winterizing the heat pump alone: do not reconnect the inlet and outlet connectors, instead place
two stops (supplied) on the condenser water inlet and outlet.
4. Maintenance
4.1 Maintenance instructions
A general servicing of the appliance is recommended both when winterizing and when restarting in order
to ensure the proper operation of your heat pump, to preserve its performance and to prevent potential
failures.
Servicing costs will be borne by the user.
Do not use a high‐pressure water hose.
ensure that no foreign bodies obstruct the fan grid,
clean the evaporator with a soft brush and a fresh water jet (disconnect the power cable), do not twist or bend
the metal blades, then to clean the discharge pipe of the condensates in order to evacuate the impurities which
could block it,
clean the outside of the unit with a solvent‐free product,
check that the water condensation flows out properly during the operation of the device,
check the proper operation of the regulator,
check electrical components,
check that all metal elements are grounded,
check the tightening and connections of electric cables and the cleanliness of the electrical compartment.
4.2 Additional recommendations
In relation to the Pressure Equipment Directive (PED‐97/23/CE).
4.2.1 Installation and maintenance
the unit may not be installed close to combustible materials, or the air duct inlet of an adjacent building,
with some devices, it is essential to fit protection grids if the unit is installed in an area with uncontrolled access,
H04019‐00.A3.EN – 2013/01
ML1_Pac Alpha Ed 01-2013-noir.indd 17
and
simultaneously for 3 seconds:
and
simultaneously for 3 seconds:
the water flow diode should flash.
button for 2 seconds, then disconnect the power cable,
will be displayed for 3 seconds
will flash for 4 seconds then:
:
EN
6