SALINITY Salinity is displayed along with the gpl
(grams per litre) indicator, when the
SALINITY button (C) is depressed. If
a reading of HH appears, the salinity is
above 4.5 to 6.5 gpl (depending on pool
temperature) and is too high to measure
correctly (at normal temperatures).
Maintain salinity between 3.0 and 3.5
gpl. See Section 4.
ADD SALT The ADD SALT indicator comes on
when the flow/temp/salinity sensor
determines that the salinity level of the
pool water is too low. Maintain Salinity
between 3.0 and 3.5 gpl.
SERVICE and
The SERVICE indicator will turn on
Service Code
whenever the control system detects
a problem that requires attention. The
SERVICE indicator is accompanied by
a service code displayed on the front
panel, displayed as a three (3) digit
code. The service code(s) are displayed
twice per minute with an audible alarm.
NOTE See Section 7.2, Service Codes. Problems
can range from insufficient salinity to the DC cord not
connected.
Audible
An audible alarm (beep) sounds once
per hour, and only for the first service
Alarm
code, when a SERVICE condition is
detected. The alarm can be cleared by
pressing and holding the SALINITY
button (C) for five (5) seconds. The
audible alarm can be cleared for 24
hours or until the power to the unit
is turned off and back on whichever
comes first. However, the audible alarm
will return if a new problem is detected.
NOTE The audible alarm can be permanently disabled
by removing the jumper from J2 on the control/
power center power interface board.
|
Zodiac
Nature
Fusion Soft
Installation and Operation Manual
®
ENGLISH
Audible
Audible alarm operation and volume
Alarm
control can be adjusted. To adjust
Volume
volume control, press and hold the
Control
TEMPERATURE button (D) for 15
seconds. The system will beep once
when pressed, once after 10 seconds
and once after 15 seconds. Release
the key after the third beep. Press the
SALINITY button (C) within five (5)
seconds to enter the temperature change
screen.
NOTE The boost cycle is normally
activated after 10 seconds,
however, if the key is held down
until after the third beep at 15
seconds, the Boost mode will
not be changed.
The system will display a '1'
followed by 'C' or 'F'. Press the
TEMPERATURE button (D) to move
to the second parameter screen. The
screen will display a 0, and the alarm
volume will be fully reduced. The
system will occasionally show a '2' to
display the screen number. Press the
arrow button B to increase the volume
and the arrow button A to reduce the
volume. The volume increments from
0 to 100 in 20 steps. After each press
of the arrow buttons, the alarm will
activate to demonstrate the current
volume level. When the alarm volume
has been adjusted to the desired setting,
press the SALINITY button (C) to
confirm the new alarm volume setting.
The change will be stored in permanent
memory. If you do not wish to keep the
change, wait five (5) seconds, and the
change screen will 'time out' and return
to normal operation without keeping
any changes to the system. Any changes
made to the alarm volume will NOT be
saved if this occurs.