• The AquaLink RS PureLink power center
converts AC power into low voltage DC current
which is required by the cell to perform the
electrolysis.
• The LCD display offers monitoring of
chlorine production, cell modes, salinity level,
temperature, water flow and diagnostics.
• The chlorine generator electronics are connected
with the pool circulation pump electrical source
so that the electrolytic cell only operates when
the pool pump is on. The flow portion of the flow/
temp/salinity sensor is a backup device only.
Nature2 Fusion Sanitizing Vessel
• The sanitizing vessel uses a combination of an
electrolytic cell and a mineral cartridge. The
electrolytic cell contains bipolar electrodes which
perform the electrolysis and produce chlorine
when energized with DC current. Chlorine is
generated as pool water containing salt passes
through the cell. The chlorine production can
be varied by either adjusting the Chlorine
Production Level on the power center or by
2.3
Product Specifications
Model Number
Capacity
Maximum operating pressure
Minimum flow rate
Maximum flow rate
Salt Level Requirement *
Recommeded Salt Level *
Vessel Dimensions
Power Pack Dimensions
Vessel Weight
Power Pack Weight
* Do not exceed 3,500 ppm
The life expectancy of the electrolytic cell is 10,000 hours under normal use. When replacing the cell, only use
replacement cells that clearly state that it is a replacement cell for the Nature
Registration Number 30481, PEST CONTROL PRODUCTS ACT.
|
Zodiac
Nature
Fusion Soft
Installation and Operation Manual
®
2®
varying the number of hours the Nature2 Fusion
Soft is on each day.
automatically cleans the electrodes once
every three (3) hours by reversing polarity.
This does not interrupt the production
of chlorine.
The mineral cartridge delivers
controlled trace amount of minerals that work
in conjunction with the chlorine to maintain an
algae-free pool.
Flow/Temperature/Salinity/Sensor
• The flow portion of the flow/temp/salinity sensor
helps detect if there is adequate water flow
through the vessel.
• The salinity portion of the flow/temp/salinity
sensor detects the level of salt in the pool water.
This salt level is displayed in grams per litre
(GPL)* on the liquid crystal display (LCD)
whenever the salinity button is pressed. This
eliminates the need for manual pool water salinity
testing.
• Pool temperature is displayed by pressing the
temperature button.
*1 gram per litre (GPL) = 1000 ppm (parts per million)
Nature
Fusion Soft
2
FSOFT1400C
Up to 113,600 L. (30,000 gal)
345 kPa (50 psi)
114 lpm (30 gpm)
455 lpm (120 gpm)
3,000 - 3,500 ppm
3,000 ppm
42 cm x 40 cm x 37 cm (16.5" L x 16" H x 14.5" D)
37 cm x 25 cm x 17 cm (14.5" L x 10" H x 6.5" D)
5 kg (11 lbs)
11.3 kg (25 lbs)
Fusion Soft,
2
ENGLISH
Page 9
2
The Nature
Fusion Soft