Page 22
ENGLISH
3.11 Connection to the AquaLink
Control System
CAUTION
Do not over-tighten the strain relief fitting. Over-
tightening can cause damage to the flow/temp/
salinity sensor cable.
The AquaLink RS is a multi-function pool controller
that can fully control the function of the Nature
Soft chlorine generator. The chlorine generator user
interface will display "JA" when any of its buttons
are pressed while the AquaLink RS is in control.
Adjustment of the chlorine production rate or Boost
mode can be controlled from the main menu of the
AquaLink RS controller (All Button, OneTouch™,
or PDA). Boost mode can also be activated from the
chlorine generator user interface while the AquaLink RS
is online. Refer to the AquaLink RS Operation Manual
(or AquaLink RS PDA Operation Manual) for more
information. The chlorine generator's user interface will
display temperature, salinity, service codes, and LED
indicators as normal.
To Filter Pump
240 VAC
Figure 13.
Power connection between AquaLink RS enclosure and Nature
Red, 4-Pin
Terminal Bar
OPTIONAL
AquaLink RS Power Center
Figure 14.
Wiring Nature
Zodiac
Nature
®
RS
®
Fusion
2
AquaLink RS Power Center
(High Voltage Area)
Filter Pump Relay
Aux. 3 Relay
4 3 2 1
Chlorine Generator
Power Interface
Board
Fusion Soft Control Center to an AquaLink RS Control System
2
|
Fusion Soft
Installation and Operation Manual
2®
NOTE The Nature
electronics will communicate with AquaLink RS
using firmware versions JJ or later.
3.11.1 Wiring Nature
Power Pack to a Zodiac
AquaLink RS
In the AquaLink RS power center enclosure, wire the
Nature
Fusion Soft power pack input power directly
2
to the LOAD SIDE of the filter pump relay (see Figure
13).
The AquaLink RS and Nature
(4) wire connection to communicate and can be wired
up to 150 m (500 ft) apart. Any outdoor rated four (4)
conductor cable, minimum 22 AWG (0.326 mm
be used. Locate the appropriate screw terminals on the
circuit board according to Figure 14. Wire the Nature
Fusion Soft from the red 4-pin terminal bar to the
AquaLink RS red 4-pin terminal bar.
To Breaker
Panel
NOTE
The screw terminals are removable to aid in
installation.
IMPORTANT
Attach the Nature
the like-numbered screw terminals on both the
Nature
Fusion Soft and AquaLink RS as shown in
2
Figure 13.
Fusion Soft and PureLink
2
Fusion Soft
2
Fusion Soft use a four
2
Nature
Fusion Soft Power Pack
2
Fusion Soft enclosure.
2
Fusion Soft wires to
2
TM
), can
2
2