Section 7.

Troubleshooting

Always turn pump off prior to attempting service or repair. Your pump and filter system is operated under pressure
and pressure must be released before you begin to avoid system damage or personal injury. Open the air relief
valve on your pool filter to release the pressure in the system.
7.1

Problems and Corrective Action

Problem
Low or no chlorine.
No display on LCD (Screen is
blank).
|
Zodiac
Nature
Fusion Soft
Installation and Operation Manual
®
WARNING
Possible Cause
Low stabilizer (cyanuric acid) level in pool
water.
Insufficient operating hours of the unit (for
outdoor pools only).
CHLORINE PRODUCTION percentage set
too low or off at 00%.
Recent increases in weather temperature
without increasing the chlorine production of
your unit.
Temporary loss of chlorine due to heavy
organic load - rain, leaves, fertilizer or heavy
bather load. Pets using pool.
Low (less than 2.5) gpl salt level in pool
water.
High nitrate level.
Metals present in pool water.
New pool water. Not shocked properly upon
startup.
Clogged or dirty cell.
No Power to Unit.
Loose ribbon cable between front and back
PC board.
Incorrectly wired. Unit not wired for 240 VAC.
Loose or bad connection at white connector
between transformer and PC board.
ENGLISH
Corrective Action
Add stabilizer to maintain 30 - 100 ppm.
Increase chlorine production by pressing
the Chlorine Production Rate Adjustment
button (arrow button B). See Section 5,
Operating Instructions.
Increase chlorine production by pressing
the Chlorine Production Rate Adjustment
button (arrow button B). See Section 5,
Operating Instructions.
Set "Boost" mode and allow to run for
24 hours. Recheck. If still too low, Super
Chlorinate with outside source. (Take
pool water sample to a qualified service
representative.) See Section 5, Operating
Instructions.
Test salinity by pressing the Test Salinity
button. See Section 4, Table.
Contact a qualified service representative.
Contact a qualified service representative.
Super Chlorinate Pool. See Section 5.4,
Startup.
Remove cell for inspection. Clean
if necessary. See Section 6, User
Maintenance Instructions.
Check power. Turn on pump.
1. Defective automatic timer or pump
switch.
2. Loose connection at automatic timer or
pump switch.
Check that ribbon cable is fully inserted
into connector.
Check that unit is correctly wired for 240
VAC and connected to 240 VAC.
Check connector at white plug to insure
proper connection. If burnt connector
contact a qualified service representative.