Troubleshooting
Problems
Possible causes
1. No current in the outlet
2. Defective extension cable
Engine not starting
3. Wrong feeder cable
4. Defective switch, condenser
Wrong engine running
1. Wrong connection
direction
1. Two-hand switching lever adjustment
Splitting knife not moving
1.
2.
3.
Splitter has no power
4.
5.
After being pressed, the
1. Defective fuse, etc.
green switching button not
2. 2 phase running
staying in place
1.
Hydraulic pump whistling;
splitting knife running jerky
2.
Wrong rotation direction
Too little hydraulic oil
Starting rod is bent; the hydraulic lifter is
not pressed to the full extent
Wood with too many knots - splitting knife
gets jammed
Operating arm is bent
Oil loss, surface is dirty
Too little hydraulic oil in the tank
Remedy
1. Check the network protection
2. Pull out the plug – check it and replace it if necessary
3. Connection with 5 cores with a cross section of 2.5
2
mm
4. Have the appliance checked by an electrician
1. Turn the phase changer in the appliance plug using a
screwdriver
1.  Check the oil level
 Defective control valve must be replaced in a
service centre only
1. Change the rotation direction
2. Add hydraulic oil
3.  Check all screws on the starting rod mechanism
 Adjust the pull rod (pic. 10/B); by this,
 the hydraulic lifter will be pressed to the full extent.
4. Lubricate the splitting knife with fat.
5. Return the operating arm to the starting position.
1. Check the cable
1.  Tighten the screwing
 Replace the hoses
2. Add hydraulic oil