General Description; Safety Instructions / Maintenance - Eneo VKC-1374/IR Mode D'emploi

Boîtier de connexion et alimentation, anti-intempéries, pour vkc-1356/ir
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation and Operating Instructions
VKC-1356/AK
Camera Connection Box, weatherproof,
for VKC-1356/IR

1. Safety Instructions / Maintenance

• R ead these safety instructions and the operation manual first before you
install and commission the unit.
• Keep the manual in a safe place for later reference.
• T he system may only be commissioned and maintained by personnel
authorized to do this and it must only be carried out in accordance with
relevant standards and guidelines.
• P rotect your unit from contamination with water and humidity to prevent it
from permanent damage. Never switch the unit on when it gets wet.
Have it checked at an authorized service center in this case.
• N ever operate the units outside of the specifications as this may prevent
their functioning.
• D o not operate the unit beyond their specified temperature, humidity or po-
wer ratings. Operate the unit only at a temperature range of 0°C to +50°C
and at a humidity of max. 80%.
• T he unit should be protected against excessive heat, dust, damp and
vibration.
• T o disconnect the power cord of the unit, pull it out by the plug.
Never pull the cord itself.
• P ay attention when laying the connection cable and observe that the cable
is not subject to heavy loads, kinks, or damage and no moisture can get in.
Do not attempt to disassemble the camera board from the dome.
• Contact your local dealer in case of malfunction.
• M aintenance and repair have to be carried out only by authorized service
centers.
Before opening the cover disconnect the unit from mains input.
• T he warranty becomes void if repairs are undertaken by unauthorized
persons. Do not open the housing.
• The connection cable should only be changed by Videor E. Hartig GmbH.
• Only use original parts and original accessories from Videor E. Hartig GmbH.
• D o not use strong or abrasive detergents when cleaning the dome.
Use a dry cloth to clean the dome surface. In case the dirt is hard to remove,
use a mild detergent and wipe gently.
• During assembly, care must be taken to ensure that existing seals are
correctly inserted and are not displaced as a result of assembly.
You must not continue to use damaged seals.
NOTE: This is a class A digital device.
This digital device can cause harmful interference in a residential
area; in this case the user may be required to take appropriate
corrective action at his/her own expense.

2. General Description

• Camera Wall Mount Connection Box
• Mains Voltage Connection and Remote Supply
• Control and Measurement Point
• 2 pin Video Signal Terminal and RS-485 Interface
• 6 pin Screw Terminal for Video and Control
• Di-cast Aluminium Casing with 2 Cable Glands
• Protection Rating: IP65
• Accessories: Cable MCAB-2, Thread Adapter 3/4"
3. Installation
• Using the guide pattern as a template, cut a round opening the wall.
• D rill four holes according to the guide pattern, then insert anchor screws
into the drilled holes.
• Fix the junction box to a wall using four anchor screws.
• C amera cables go through Holder Grand on the front of the junction box,
and fix them by 4 screws.
4 Connection to Camera Controller
A Type Model (Power/Video)
1
2
3
4
5
6
No. Wire Colour
Function
1
Red
12VDC
2
Orange
GND
3
Black
GND (Video)
4
Yellow
Video Out
5
Green
Not used
6
Brown
Not used
Anchor screw
B Type Model (Power/Video/RS-485)
1
2
3
4
5
6
No. Wire Colour
Function
1
Red
12VDC
2
Orange
GND
3
Black
GND (Video)
4
Yellow
Video Out
5
Green
RS-485 (+)
6
Brown
RS-485 (–)