Bosch EV2000 Série Manuel D'installation Et D'utilisation page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

en | 6 | EV2000 Series Wallbox Charger Installation and Operation Manual
Installation and Operation Manual
3.
Fasten cable gland to secure wires.
NOTE: To ensure protection from the elements, make
sure to use certified IP55 (or above) cable
glands.
4.
Remove lid of terminal block and connect the wiring
to the correct terminals. See the following informa-
tion for specific model connections.
Wiring requirements are dependent on the model
type and between single and three-phase models.
WARNING! Cable color coding may be
defined differently depending on the
region.
Single-Phase: Wiring the 240 / 277V Models
579604 | REV. C | June 2020
` Conduit hub and conduit size M50 according to EN
61386-24.
` Connect the power wires of 2 x RNB70-10 ring terminal
with cable lugs to the input terminal marked with "L"
and "N" using 2 x M10.0 screws with torque of 88.4
lb-in.
` Connect the ground wire of RNBS14-6 into the earth
terminal marked with ground symbol using 1 x M6 screw
with torque of 17.7 lb-in.
Three-Phase: Wiring the 480V Model
` Conduit hub and conduit size M50 according to EN
61386-24.
` Connect the power wires of 4 x RNB14-6 ring terminal
with cable lugs to the input terminal marked with "L1",
"L2", "L3" and "N" using 4 x M6.0 screws with torque of
28.7 lb-in.
` Connect the ground wire of RNBS14-6 into the earth
terminal marked with ground symbol (
screw with torque of 17.7 lb-in.
Three-Phase: Wiring the 208V Model
` Conduit hub and conduit size M50 according to EN
61386-24.
` Connect the power wires of 3 x RNB38-6 ring terminal
with cable lugs to the input terminal marked with "L1",
"L2" and "L3" using 3 x M6.0 screws with torque of 28.7
lb-in.
` Connect the ground wire of RNBS14-6 into the earth
terminal marked with ground symbol (
screw with torque of 17.7 lb-in.
` Neutral wire is not required.
) using 1 x M6
) using 1 x M6
Bosch Automotive Service Solutions Inc.

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

El-52240El-52240-3pd

Table des Matières