Praesideo 4.0
Clause / Requirement
14 Design requirements
14.2 Documentation
14.2. 1 The manufacturer shall prepare installation and user
documentation, which shall be submitted to the testing
authority together with the s.s.c.i.e. This shall comprise at
least the following:
b technical specifications of the inputs and outputs of the
s.s.c.i.e., sufficient to permit an assessment of the
mechanical, electrical, and software compatibility with
other components of the system (e.g. as described in
ISO 7240-1), including where relevant
3
the maximum number of alarm inputs from an
emergency detection system
c
installation information, including
1
the suitability for use in various environments,
2
how the requirements of 14.3.3 and 14.5.3 can be
met if the s.s.c.i.e. is contained in more than one
cabinet,
3
how the requirements of 14.3.3 and 14.5.4 can be
met if the s.s.c.i.e is designed to be used with
power-supply equipment contained in a separate
cabinet,
4
mounting instructions, and
5
instructions for connecting the inputs and outputs.
14.3.3 The s.s.c.i.e. may be housed in more than one
cabinet. If the documentation shows that the cabinets may
be installed in locations distributed within a site, then all of
the mandatory manual controls and indicators shall be on
one cabinet or on cabinets declared to be suitable only for
mounting adjacent to each other.
NOTE For the purposes of 14.3.3, adjacent cabinets are
those that are mounted in physical contact with each other.
14.8 Indications on alphanumeric displays
14.8.2 Alphanumeric displays used for mandatory
indications shall have at least one clearly distinguishable
window, consisting of at least two clearly identifiable fields.
14.8.3 If not included in the displayed information, the
purpose of each field shall be clearly labelled.
14.8.4 Where roman characters are used, a field shall be
capable of containing at least the following:
a
at least 16 characters where the display of a functional
condition uses a cross-reference to other information to
identify the location;
b
at least 40 characters where the display is intended to
include the complete information on the location of a
functional condition.
14.8.5 Where other characters are used, a field shall be
capable of containing at least the following:
a
at least 4 characters where the display of a functional
condition uses a cross-reference to other information to
identify the location;
b
at least 8 characters where the display is intended to
include the complete information on the location of a
functional condition.
14.9 Colours of indications
14.9. 1 The colours of the general and specific indications
from light-emitting indicators shall be as follows:
b
yellow for indications of
3
emergency loudspeaker zones in the test state.
Bosch Security Systems B.V.
Compliance
The inputs and outputs for audio and control are described
in the IUI, including the technical data, system functions,
configuration instructions, compliancy to standards. This
includes the information as requested in 14.2. 1 b 3.
The IUI contains all information as requested in 14.2. 1 c
1-5.
In case Praesideo is installed in multiple cabinets in
locations distributed within a site, the installer must arrange
that all mandatory manual controls and indicators are on the
same location, either by installing them on a single cabinet
or on adjacent cabinets that are mounted in physical
contact with each other.
The display of the network controller is used to display
mandatory indications. It consists of two separate lines of
text, each representing a specific field, clearly identifiable.
Indication of the voice alarm condition is by means of the
text 'Emergency' and the name of the key that activated the
voice alarm condition. Indication of the fault warning
condition is by means of the text 'Faults' and an indication
of the number of active faults in the system. Individual faults
with details are shown in a menu structure.
The display of the network controller consists of two lines
with 16 characters each. It uses a menu with rotary knob
navigation to select additional detailed information about
functional conditions.
Not applicable, see 14.8.4.a.
Not applicable, see 14.8.4.
The test condition is an optional function and is not
supported by Praesideo. See 10.
Installation and User Instructions
Signature
IUI-PRAESIDEO_4.0 | V1.0 | 2013.01
en | 81