Fig. 9c Through the floor and basement
Fig. 9d indirecitly through an outside wall
Fig. 10 Mounting of external air supply connection
1. Place the external air supply connection with the hose
clamp on the outside air hole.
2. Tighten with screwdriver.
4.4 Location of approval label
Fig. 11 Approval label
1. The approval label is located at the bottom of the stove.
4.5 Chimney and flue pipe
The fireplace must only be connected to a chimney and
flue pipe approved for solid fuel fireplaces with flue gas
temperatures as specified in «2.0 Technical Data».
For flue pipe dimension see "2.0 Technical Data". NB:
The chimney's diameter must be at least as big as the flue
pipe: Ø150 mm flue pipe - 177 cm
Connection to the chimney must be carried out in
accordance with the chimney supplier's installation
instructions.
Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the fireplace and the hole in the chimney. See fig. 1 for
minimum dimensions.
Use a flue pipe bend with a sweep hatch to allow sweeping.
Flue pipe bends with any change in direction influence/
reduce the chimney draught. This effect also applies
when horizontal flue pipes are used. Please note that it
is extremely important for connections to have a degree
of flexibility. This is to prevent any movement in the
installation leading to the formation of cracks.
For recommended chimney draught, see «2.0 Technical
Data».
NB! The minimum recommended chimney length is 4 m from
the flue pipe insert. If the draught is too strong, a flue pipe
damper can be installed and used to reduce the draugh
If a flue damper is fitted it must be of a type, which does not
block the flue totally. The damper should be easy to operate
and incorporate an aperture within the blade, which in a
continuous area occupies at least 20 cm
sectional area of the blade if this is greater.
The position of the damper should be recognizable from the
setting of the device.
If a draught regulator is fitted the minimum cross sectional
area requirement shall not be applicable but the device should
be easily accessible for cleaning.