Water Supply And Drain Connections; Start-Up Procedure - Hoshizaki FM-120EE Notice D'installation

Masquer les pouces Voir aussi pour FM-120EE:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
5. WATER SUPPLY AND DRAIN
CONNECTIONS
(For the U.K. only, the connections must be in
accordance with current requirements of the Model
Water Byelaws 1986 SI No. 1147)
* Only potable water should be used for the icemaker.
* Water supply pressure should be minimum 0.5 bar
and maximum 8 bar. If the pressure exceeds 8 bar,
use a proper pressure reducing valve. Do NOT throttle
back the supply tap.
* A plumbing permit and services of a licensed plumber
may be required in some areas.
* The icemaker drain is gravity flow, so ensure drain
pipe has an adequate pitch or fall.
* Water should drain into an open trap.
1) Attach angled end of white flexible inlet hose
(accessory) to the G3/4 fitting at the top rear of the
icemaker as indicated, ensuring rubber sealing
washer is correctly positioned. Hand tighten
sufficiently to provide leak free joint.
2) Attach the other end of inlet hose to the water tap,
noting washer is correctly positioned before hand
tightening as above.
3) Attach grey flexible outlet hose (accessory) to the
R3/4 fitting at the bottom rear of the icemaker as
indicated, confirming fitment of rubber washer before
finally hand tightening the joint. This pipe can be
cut to length as necessary to suit position of main
drain.
Inlet Hose
Outlet Hose
Fig. 3
Water Supply
Inlet G3/4
Drain Outlet
R3/4
Fig. 4

6. START-UP PROCEDURE

1) Check that the power supply cord is disconnected.
2) With the Front Panel (Left) removed, check that
the Operation Switch on the Control Box is turned
on.
Front Panel
(Left)
Air Filter
Fig. 5
Circuit
Motor
Breaker (6A)
Protector *
Control Box
* 3A (FM-120EE, CM-110EE)
1A (FM-80EE)
Fig. 6
3) Replace the Front Panel (Left) and Top Panel in
their correct position.
4) Open the water supply tap.
3
ENGLISH
Water Supply Tap
Inlet Hose
Control Box
Condenser
Operation
Switch

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fm-120ee-nCm-110eeFm-120ee-50Fm-120ee-50-nFm-80eeFm-80ee-n

Table des Matières