If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.
* The non-rewirable plug must never be used without
a fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer's
reference number stamped on the plug.
Supply of replacement fuse covers can be obtained
from Hoshizaki Parts/Service Centres.
Fuses should be rated at 13A and approved to
BS 1362.
5. WATER SUPPLY AND DRAIN
CONNECTIONS
WARNING
Connect to potable cold water supply only.
Note: A plumbing permit and services of a licensed
plumber may be required in some areas.
* The connections to the mains water supply
must be made in accordance with the countries'
current requirements of the Water Supply or
Water Fittings Regulations.
* I c e m a k i n g w a t e r m u s t b e p o t a b l e w a t e r.
Where scaling can be caused by water quality,
installation of an external filter or softener
is recommended. Contact your local water
treatment professional or Hoshizaki service
agent.
* Water supply pressure should be minimum 0.05
MPa (0.5 bar) and maximum 0.8 MPa (8 bar).
If the pressure exceeds 0.8 MPa (8 bar), use a
proper pressure reducing valve. Do NOT throttle
back the supply tap.
* The icemaker drain is
gravity flow, so ensure
d r a i n h o s e h a s a n
adequate pitch or fall.
* Drain lines should not be
installed directly to the
sewer system. A vertical
air gap of a minimum of
5 cm should be between
All manuals and user guides at all-guides.com
Inlet Hose
Outlet Hose
5cm air gap
Floor
Drain
Fig. 7
5
the end of the drain hoses from the icemaker and
storage bin and the floor drain.
* Be sure to use the new hose-sets supplied with
the appliance. Do not reuse any old hose-sets.
1) Attach angled end of white flexible inlet hose
(accessory) to the G3/4 fitting on the rear of the
icemaker as indicated, ensuring rubber sealing
washer is correctly positioned. Hand tighten
sufficiently to provide leak free joint.
2) Attach the other end of inlet hose(s) to the water
tap, noting washer(s) is/are correctly positioned
before hand tightening as above.
3) Attach grey flexible outlet hoses (accessories) to
the R3/4 fittings as indicated, confirming fitment
of rubber washers before finally hand tightening
the joints. These pipes can be cut to length as
necessary to suit position of main drain.
Fig. 8
6. START-UP PROCEDURE
1) Check that the power supply cord is disconnected.
2) Move the Operation Switch on the Operation Panel
to the "ON" position.
ENGLISH
Water Supply
Inlet G3/4
Drain Outlet
R3/4
Water Supply Tap
Inlet Hose