4.4 Application conditions
Media:
Neutral gases and liquids,
Technical vacuum
Ambient temperature:
max. +55 °C
Permitted medium temperature depending on sealing material:
FKM
–10 ... +120 °C
EPDM
–30 ... +120 °C
PTFE/PEEK
max. +180 °C
Degree of protection:
IP65 with device socket
Temperatures for valves with UL/UR approval
Non-hazardous fluids
Fluid
–30 ... +140 °C
Ambient
–30 ... +55 °C
Operating duration:
Unless otherwise indicated on the type label,
the solenoid system is suitable for continuous
operation.
5
INSTALLATION
DANGER!
Risk of injury from high pressure in the equipment.
▶ Before loosening the lines and valves, turn off the pressure and
vent the lines.
Risk of injury due to electrical shock.
▶ Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations for
electrical equipment.
WARNING!
Risk of injury from improper installation.
▶ Installation may be carried out by authorized technicians only and
with the appropriate tools.
Risk of injury from unintentional activation of the system and an
uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following assembly, ensure a controlled restart.
6
5.1 Installation of coil
WARNING!
Risk of escape of media.
When a sticking nut is loosened, medium may escape.
▶ Do not tighten sticking nut any further.
Risk of injury due to electrical shock.
If the protective conductor contact between the coil and body is
missing, there is danger of electrical shock.
▶ During installation insert the plastic ring into the body journal. The
plastic ring must not project over the octagonal nipple.
▶ Check protective conductor contact after installing the coil.
Overheating, risk of fire.
If the coil is connected without a pre-installed valve, the coil will overheat
and be destroyed.
▶ Connect the coil with a pre-installed valve only.
Hazardous fluids
–10 ... +140 °C
–10 ... +55 °C
english
4.5 Circuit function
2 (A)
Circuit function A
1 (P)
english
Medium leaking through damaged connections.
▶ Do not damage sealing surfaces of the body connections.
Danger due to unsuitable screw connections.
▶ Use compatible screw connections only.
→
Check pipelines for dirt and clean.
→
Install a dirt filter before the valve inlet (0,2...0,4 mm).
Installation position:
any, actuator preferably upwards.
NOTE!
Caution risk of breakage.
▶ Do not use the coil as a lever arm.
Valve body must not be installed under tension.
Sealing material must not get into the device.
→
Seal the pipe connection with an elastomer seal or PTFE tape.
Ensure that no sealing material gets into the device.
→
Observe direction of flow: from 1 → 2 (from P → A).
→
Hold the device with a open-end wrench on the body and screw
into the pipeline.
Nut
4 x 90°
Plastic ring
Fig. 1:
Installation of coil
english
Type 6240
Servo with positive lift
5
O-ring
max. 5 Nm
7