4. Installation, Connection and Operation

4.1 Installing the Housing

1.
To install the housing, undo the two Allen screws (c) (see fig. 2) and pull the mounting plate (3) from the housing.
2.
Fix the mounting plate to the internal wall, ceiling, external wall etc. using the enclosed fixing screws and plugs as appropriate. Before carrying this out, check
that the surface is strong enough.
3.
The power supply and signal cables can be fed directly through the mounting plate and the cable entry (e) found at the side (see fig. 3). If necessary, the cable
can again be fixed to the mounting plate with the enclosed cable clip in order to relieve strain.
NOTE: If the power supply unit that is provided as an optional extra is used, it is fitted to the surface instead of the mounting plate but following exactly the
same instructions. In this case the mounting plate is not required.
Fig. 3
j
k l
4.2 Connector Cables

4.3 Connection using the Optional Power Supply Unit VHU-NT1

The power supply base is an option supplied for the CANDID range of housings. It is designed for installation sites where a mains voltage supply is available. The
power supply base is designed to be used exclusively with the CANDID range of housings and can only be operated with these housings.
Instead of the mounting plate (3), the mounting plate (5) with integrated power supply is fitted (see figs. 3 and 4) as described in section 4.1.
3
e
5
i
e
red
Camera
black
brown
Screen heater
orange
Video output
+12VDC
0VDC
12-14VAC/DC
12-14VAC/DC