Fig. 4
VHU-NT1 Power supply
1. The unit base with integrated power supply is installed with the round-head screw (i), wall plug (j), screws for the cable clip (k) and cable clip (l) which can be
found in the accessories.
2. The power supply and signal cables are fed through the cable bushing of the mounting plate with integrated power supply. The power supply cable is connected
to the power supply terminal using the enclosed 4 pin connection block.
3. The video cable can be extended in the articulated arm (BNC connection).
4. Care must be taken that the connection cables are laid as centered as possible close to the power supply unit so that the range of movement of the articulated
arm is not restricted.
5. The power supply unit base should only be attached to a flat surface which is uniform to less than 1 mm in the area where the base is attached.
6. Figure 6 shows the assembly location of the housing and power supply base. The power supply base is designed for hanging or horizontal installation.
Intermediate positions are possible.
7. It is not allowed to install the base as shown in figure 6. This way of installation is crossed out in the drawing.
8. Care should be taken that the cable is fed from below through the breakout if the base is installed in a horizontal position.
9. All cables entries must be sealed with standard sealing material (e. g. silicone) to comply with the protection class.
10. The cable can also be fed directly from the wall to the power supply base.
11. The connection between mains supply and connection block has to be double isolated. Please use the attached silicone isolation pipes.
Fig. 5
Mounting position incl. power supply unit base
230V
N
L
5
+ 12V
0V
14VAC
14VAC
Screen heater
Camera