Steinberg Systems SBS-KW-300AW Mode D'emploi page 12

Masquer les pouces Voir aussi pour SBS-KW-300AW:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Press
to enter Auto-Zero option; and press
Auto-Zero can be set to 0 (disabled), 2 (2%F.S.), 4 (4%F.S.), 10 (10%F.S.), 20 (20%F.S.),
50 (50%F.S.).
Press
to enter Manual-Zero option; and press
option
Manual-Zero can also be set to 0 (disabled), 2 (2%F.S.), 4 (4%F.S.), 10 (10%F.S.), 20
(20%F.S.), 50 (50%F.S.).
Press
to enter Backlight option; and press
Backlight can be set to off (disabled), 5 (5sec), 15 (15sec), 30 (30sec), 60 (60sec), on
(never).
EN
When Backlight is set to 5, 15, 30, or 60, scale turns off backlight in corresponding
seconds after it is stable.
When Backlight is set to off, backlight is disabled, and never turns on
When Backlight is set to on, scale never turns off backlight, no matter it is stable or
not
Press
to exit the Settings Mode.
NOTE: Settings (SETUP) for the scales SBS-KW-300/100-0, SBS-KW-300/100 and SBS-
KW-1TC are similar to the SBS-KW-300AW, SBS-KW-300AB and SBS-KW-300AR sca-
les settings (SETUP), however scales SBS-KW-300/100-0, SBS-KW-300/100 and SBS-
KW-1TC have some additional service settings („dPS", „oLd" and „dc") which should
not be changed – displayed values should be confirmed by ZERO|TARE button without
any changes.
to change Auto-Zero option.
to change Manual-Zero
to change Backlight option.
23
4. CALIBRATION applicable to scale models SBS-KW-300AW, SBS-KW-300AB and
SBS-KW-300AR
Item
Operations
Press
and keep pressing for 1 second.
Press
simultaneously, and keep pressing
for 1 second.
Full scale
Press the
Resolution
Press
to go to resolution
parameter. Press
Resolution.
Decimal
Press
to go to decimal
Point
point parameter. Press
to change decimal point.
Item
Operations
Zero Calibration
Press
button
Load1 Calibration
Press
button
Load2
Press
button
Calibration
Press
button
Display
Notes
SETUP
simultaneously,
SCALE
300
Value 300
button
should be set
E 1
Resolution
can be set to
to change
1/2/5
Pt 0
0: XXXXX
1: XXXX,X
2: XXX,XX
3: XX,XXX
Display
Notes
LOAD 0
HALF
hang a hook
150 kg
FULL
hang a hook
300 kg
End
End of calibra-
tion
24
EN

Publicité

Table des Matières
loading

Table des Matières