5.5 PRIMING Menu

PRIMING
Each time the pump starts, the system performs the priming procedure (if enabled).
Priming consists of two phases:
- At the end of pump startup (as described in par. 3.2), the flow is checked; if it regular, Priming has already been
completed and it passes to the conditions of the active setpoint.
- If this is not the case, the system has discharged and must be primed again: it now enters the second phase, where
the pump is activated at Priming Speed, until it is primed or at any rate for all the Priming time
ENGLISH
PARAMETERS
Config
PARAMETERS
IN-0
OUT
AN
AP ext
IN1-4
PARAMETERS
VALUES
Enable
Yes/No
Speed
50%-100%
Time
1-30 min
68
NC
Normally Closed
VALUES
DESCRIPTION
The relay signals when the pump
RUN
is working
The relay signals when the pump
FAULT
fails
NOTE: NC or NO depends on the connection.
For the version with 5Pin connector the contact
type is chosen, whether NO or NC
DESCRIPTION
Status of the digital Input
Output relay status
Status of the Analog Input
Value of the enabled External Speed
Status of the digital inputs
DESCRIPTION
Enables or disables the Priming function
that occurs at each start. It is usually
disabled in installations below water level.
Sets the maximum speed during priming,
which can be reduced in the case of
systems unable to withstand high speeds.
Sets the duration time in the priming
phase.
At the end of this time, if priming has
been successful, it proceeds regularly
according to the active setpoint. But if
priming has not been successful, it goes
into "NoPriming" fault status ("Pump not
primed" block). See chapter 6.