UNIT OF MEASURE
PUMP LIMITS
SVRS (only for models with SVRS)
Before starting the pump with SVRS disabled, always check that there is no one in the pool.
For example, by pressing the QuickClean button you can now start the pump without the SVRS being able to trip.
When the pump is running, the inactive SVRS condition is indicated by the flashing of the red alarm LED (
and by a flashing message on the display (homepage).
ADJUSTING THE VISOR
ENGLISH
PARAMETERS
VALUES
Head H
m (metri)
ft (feet)
Flow Q
m3/h
US GPM
l/min
Temperature
°C
°F
PARAMETERS
VALUES
Head Hmax
E.swim 150
5 m - 16 m
E.swim 300
6.5 ÷ 26.3 m
MAX
Flow Qmax
E.swim 150
10 m3/h - 30
m
/h
3
E.swim 300
25 ÷ 42.6 m
Note: if the upper limits H
than "MAX", it is possible to set the setpoints even at values
larger than the limits; however, during activation these upper
limits will never be exceeded (self-limitation of the system) and the
setpoints may not be reached.
PARAMETERS
VALUES
Auto
Restarting
Manual
Disabling time
1 min-60
SVRS
enable/disable
PARAMETERS
VALUES
Backlight
0-100%
Sleep Time
20 sec - 10 m /
always
63
DESCRIPTION
Sets the unit of measure for the
Head
Sets the unit of measure for the
Flow rate
Sets the unit of measure for the
Temperature
DESCRIPTION
If the system is not able to bear
pressures or flows that are too high,
it is possible to impose maximum
limits on the pump control.
/h
3
and Q
are set at values lower
max
max
DESCRIPTION
Enables AUTOMATIC restart after
stopping for SVRS protection.
Manual reset with the "RESET"
button is always enabled.
Allows only manual restart with the
"RESET" button after stopping for
SVRS protection.
Sets the temporary deactivation
time. Useful for cleaning the pool
with Hydraulic Cleaners.
Pressing the "ENTER" key
temporarily disables the function. A
countdown shows the time still
available before the SVRS is
automatically enabled.
DESCRIPTION
Backlight
When the backlight is off, the first
time any key is pressed has the
sole effect of restoring the
backlighting.
) (fault)