DAB E-SWIM 150 Instructions Pour L'installation Et La Maintenance page 55

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 77
ENGLISH
From this moment, the pump starting operations, with their respective speeds and operating times, will be decided
automatically, without requiring any further intervention by the operator.
Priority of Manual mode.
Even with "Auto" mode active ("Auto" LED on), pressing a "SETx" or "QuickClean" key will start the pump immediately
with the setpoint and the duration associated with the key. The pump thus goes into "Manual" mode, which has
precedence over "Auto" mode.
However, "Auto" mode remains active in the background and resumes control as soon as the function of the key that
was pressed ceases.
To deactivate "Auto" mode:
• press the "Auto" key again (the LED next to the key lights up).
If you need to stop the pump manually when it is operating, just:
• press "RUN/STOP",
the pump thus stops in any case (*), interrupting all the active modes.
This means that "Auto" mode stops and also any active manual mode ("SETx" or "QuickClean"); the
green running LED switches off. The white LED starts to blink, indicating that the system has been disabled.
When "RUN/STOP" is pressed again, the system is re-enabled and everything restarts as before. The white LED is
now lit with a steady light.
(*) Only exceptions: the Antifreeze and Antilock functions start the pump even if the system is disabled (see paragraphs
5.6).
53

Publicité

Table des Matières
loading

Table des Matières