Valve Removal - Napoleon HD81NT-1 Manuel D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.2
control access
10.2.1 inner access panel
NOTE: A new gasket will be required, when
re-installing the access panel (see "HD81-1
OVERVIEW" in the "REPLACEMENTS" section).
Remove one of the main doors, see "DOOR REMOVAL
/ INSTALLATION" section. Remove either the optional
brick or porcelain panel from the side
where the control box is located. Remove the eight
screws from the access panel.
10.3

valve removal

The valve on this appliance is piped with three fl ex connectors (one inlet, two outlets). It can be removed and
pulled forward for service.
A. Remove the optional panels.
B. Remove the air manifold, refer to Figure 1.
C. Remove inner access panel, see "INNER ACCESS PANEL" section.
D. Remove the wing nut and pivot the valve out from the slot at the bottom of the valve, refer to Figure 2.
E. Slowly pull the valve through the control door being careful not to kink the gas lines or wires.
Disconnect fl ex connectors.
F.
Replace all components before returning the appliance to service.
G. Check for gas leaks by brushing on a soap and water solution.
FIGURE 1
VALVE
ACCESS
HOLE
FIGURE 2
CONTROL
BOX
maintenance
ACCESS
PANEL
WING
NUT
VALVE
W415-2362 / A / 10.25.19
EN
45

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hd81pt-1

Table des Matières