6.0 electrical information
fi nishing
EN
WARNING
!
•
Do not use this appliance if any part has been under water. Call a qualifi ed service technician immediately to
have the appliance inspected for damage to the electrical circuit.
•
Risk of electrical shock or explosion. Do not wire 110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
•
All wiring should be done by a qualifi ed electrician and shall be in compliance with local codes. In the
absence of local codes, use the current CSA22.1 Canadian Electric Code in Canada or the current National
Electric Code ANSI/NFPA NO. 70 in the United States.
•
Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door opened or
removed.
If access to the control area is necessary AFTER INSTALLATION, remove the access panel or electrical box cover
located inside the fi rebox. The access panel and gasket must be re-installed before operating the appliance.
6.1
hard wiring connection
It is necessary to hard wire this appliance.
Permanently framing the appliance with an enclosure, requires the appliance junction box to be hard wired.
6.2
optional blower installation
See separate instructions accompanying the blower assembly.