Changing The Contact Points - Num'axes Canifugue FUG 1030 Guide D'utilisation

Ensemble anti-fugue permettant de maintenir un ou plusieurs chiens en toute liberté dans un périmètre clôturé ou non que vous définissez
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
be completely compatible with your product.
You can purchase the suitable batteries from NUM'AXES or from your distributor.
Unscrew the 4 screws on the battery cover and remove the old battery. Insert the new
battery in the position indicated on the plastic casing. A beep sound is emitted indicating
that the collar is ready for use.
If you inadvertently put the battery in the wrong way, the collar will not emit a beep sound.
Reposition the battery quickly otherwise you can damage the collar.
NB: when you change the battery, your CANIFUGUE memorises the mode previously
selected.
NB: Due to greater use during your dog's training, your first battery may not last as long
as replacement batteries.

Changing the contact points

Before replacing the contact points, make sure that you have correctly put the collar
out of service (remove the battery from its housing).
If your dog has a long-haired coat and the short contact points fitted in the factory are
unsuitable, unscrew these contact points and replace them with the long ones supplied with
the accessories. They should be moderately tightened by hand. Do not use pliers to tighten
the contact points: this may cause irreparable damage to the product.
Checking your CANIFUGUE
Checking it is working properly:
Ø
You can check that your CANIFUGUE is working properly at any time and display how it is
working using the test lamp.
Before making this check, ensure that your collar is out of service (battery removed
from the housing).
You can then place the test lamp in contact with each of the contact points (make a loop
around each contact points). Insert the battery into the collar. Connect the transmitter to
the power supply (power unit plugged into the mains).
Walk up to the antenna wire. You should first hear the warning beep sound then, as you
get closer to the wire, the test lamp should light up. Your appliance is working perfectly.
Before disconnecting the test lamp, make sure you remove the battery!