14 Troubleshooting

Item Symptom
1.
Green LED does not
flash after battery
replacement
2.
Red LED lights up after
battery replacement
3.
Red LED flashes after
battery replacement
4.
Pairing of powermeter
with bike computer
not possible
5.
Powermeter is without
any function
6.
Measured values are
not plausible
7.
Water inside the
battery compartment
Possible cause
Battery discharged
Battery discharged
Hardware defect
Battery discharged
Bike computer not in pairing
mode
Powermeter is in standby
mode
Radio contact disturbed
Battery discharged
Wrong battery type
Firmware is in an undefined
state (device is "crashed")
Zero has changed
uncontrolled
O-ring missing
O-ring worn
Battery cover damaged
Remedy
Replace battery. Use battery
CR2450.
Replace battery. Use battery
CR2450.
Install the battery again. If the
problem persists, contact customer
service.
Replace battery. Use battery
CR2450.
Set bike computer to pairing mode.
Activate powermeter by rotating
the crank.
Eliminate source of interference,
e.g. other active powermeters.
Replace battery. Use battery
CR2450.
Use battery CR2450.
Remove the battery, wait one
minute, reinstall the battery.
During the ride: Perform zeroing by
coasting without pedaling.
Insert O-ring correctly, allow battery
compartment to dry.
Replace O-ring, allow battery
compartment to dry.
Replace battery cover, allow battery
compartment to dry.
43