Sony DXC-H10/OL Mode D'emploi page 79

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

H. PHASE (horizontal phase)
Adjusts the horizontal phase when you use the external sync
signal. The initial setting is 10. Adjustable range is from 0 to
255.
SYNC/VD
1)
Switches the signal
output from the Pin 21 on the
CAMERA ADAPTOR connector (26-pin) and from the Pin
7 on the MONITOR connector (D-sub 9-pin).
Selection
Function
Outputs the sync signal.
SYNC
Outputs the VD signal.
VD
GBR/YP
P
B
R
Switches the video signal output from the CAMERA
ADAPTOR connector (26-pin) and the MONITOR
connector (D-sub 9-pin).
Selection
Function
Outputs the GBR signal.
GBR
Outputs the YP
P
YP
P
B
R
B
R
.................................................................................................................................................................................................................................
1)
You can switch the input and output with the IN/OUT select switch on the rear panel of the CMA-H10 camera adaptor.
signal.
Note
If the monitor is equipped with the signal selector, select the
same signal as the GBR/YP
B
FLASH
Sets when you use a flash connected to the FLASH
connector on the rear panel.
Selection
Function
Select this setting when using the camera without a
OFF
flash.
Select this setting when you connect a flash to the
ON
FLASH connector, and use an external frame memory,
etc. Synchronized with the input of an external trigger
signal, a flash is emitted and the WE pulse is output.
Use of the WE pulse with an external frame memory
allows you to capture full-frame still images of an HD
signal.
To select this setting, set FLD/FRM in the PAGE 3/3
menu to FRM.
For details, see the timing chart in flash emission on page
26.
P
setting on the selector.
R
25
Chapter 2 Operation
(EN)

Publicité

Table des Matières
loading

Table des Matières