Metro 800 RTS / Metro 1000 RTS
Safety input active
Pedestrian door safety
contact active
Permanent hardwired
control
Maintenance is required Indicates that maintenance is required on
Working from back-up
battery
Waiting for a command
Detection of forced entry Indicates that an attempt to open the garage
/
If other codes are displayed, contact your installer.
5.2
Following a power outage, the motor must recognise its «fully open» position
again.
Open the door fully using a memorised remote control. The door will open at a
degraded speed.
Allow the door to open to the «fully open» position.
6 -
6.1
[1]. Remove the light cover.
[2]. Unscrew and replace the defective light bulb.
[3].
Use a 24 V 21 W BA15s socket light bulb.
6.2
Check correct operation every six months (See section 4.2).
Copyright © 2016 Somfy SAS. All rights reserved
Indicates that an obstacle preventing
door closure is present between the
photoelectric cells or is in contact with
the safety sensor bar installed on the
door.
Indicates that the pedestrian door within
the garage door is open. Door operation
is inhibited.
Indicates that the hardwired control input
is permanently active. Commands from
radio remote control units are inhibited.
the installation. Contact your installer.
Indicates that the main power supply
to the motor is cut and that the motoris
powered by the battery backup pack.
door has been made from outside.
Press a button on the memorised remote
control to stop the siren.
Start a complete opening and closing cycle.
24 V 21 W max.
6.3
Li
7 -
Mains power supply
Power consumption on standby
Max. power consumption
Traction force – Peak force
Use
Number of channels that can be
memorised
Radio frequency
Integrated light
Remote controlled lighting
Operating temperature
3V CR 2430
230 V - 50 Hz
5 W
600 W (with 500 W remote controlled lighting)
800 N
1000 N
20 cycles per day with a standard rail
(tested for 36,500 cycles)
50 cycles per day with a high performance
rail (tested for 90,000 cycles)
32
433,42 MHz
< 10 mW
24 V / 21 W max. BA15s socket
230 V / 500 W max. Class 2
Halogen or incandescent only
-20 °C / +60 °C
EN
5