BFT BOTTICELLI VENERE D Instructions D'utilisation Et D'installation page 17

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
the radio menu.
2- Press within 10 sec. the hidden key (P1) and normal key (T1-T2-T3-T4) of a
transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to
enter other new transmitters.
This mode does not require access to the control panel.
OFF: Disables wireless memorizing of transmitters. Transmitters are memo-
rized only using the relevant Radio menu.
- START - OPEN setting (start-open) [ OFF ]
ON:
Input between terminals 3-4 works as OPEN.
OFF: Input between terminals 3-4 works as START.
- PED-CLOSE setting (ped-close) [ OFF ]
ON:
Input between terminals 16-17 works as CLOSE.
OFF: Input between terminals 16-17 works as PARTIAL OPENING.
- Master/Slave (master) [ OFF ]
ON:
Control panel is set up as the Master unit in a centralized connection
system.
OFF: Control panel is set up as a Slave unit in a centralized connection sys-
tem.
8.4) RADIO MENU (RADIO)
- Add
Used to add a key on a remote control to the receiver's memory.
Once memorized, it returns the number of the receiver in the memory loca-
tion (from 01 to 64).
- Add Start Key (Add start)
associates the desired key with the Start command
- Add 2ch Key (Add 2ch)
associates the desired key with the 2nd radio channel command
- Read (Read)
Checks a key of a receiver and, if memorized, returns the number of the
receiver in the memory location (from 01 to 64) and number of the key (T1-
T2-T3 or T4).
- Erase List (erase 64)
WARNING! Erases all memorized remote controls from the receiver's
memory.
- Read receiver code (cod RX)
Displays the code entered in the receiver.
- W LINK (uk)
ON =
Enables remote programming of cards via a previously memorized W LINK
remote control. It remains enabled for 3 minutes from the time the W LINK
remote control is last pressed.
Refer to the W LINK remote control's manual for the mapping of the rel-
evant keys.
OFF =
W LINK programming disabled.
Consult sections 8/9/10/11 for further information on the built-in Clonix
receiver's advanced features.
8.5) LANGUAGE MENU (LANGUAGE)
Used to set the programmer's language on the display.
There are 5 language options:
-
ITALIAN (ITA)
-
FRENCH (FRA)
-
GERMAN (DEU)
-
ENGLISH (ENG)
-
SPANISH (ESP)
8.6) DEFAULT MENU (DEFAULT)
Restores the controller's default factory settings. Following this reset, you will
need to run the autoset function again.
8.7) DIAGNOSTICS AND MONITORING
The display on the VENERE D panel gives a certain amount of useful information
both during normal operation and when faults are detected.
Diagnostics:
In the event of malfunctions, the display gives a message showing which device
needs checking:
STRT
= START input activated
STOP
= STOP input activated
PHOT
= PHOT input activated
SWO
= OPENING LIMIT SWITCH input activated
SWC
= CLOSING LIMIT SWITCH input activated
PED
= PEDESTRIAN input activated
OPEN
= OPEN input activated
CLS
= CLOSE input activated
In the event the door encounters an obstacle, the VENERE D panel stops the door
and commands it to reverse, while on the display the "AMP" message appears
Monitoring:
During opening and closing, the display shows four numbers separated by a decimal
point, e.g. 35. 4 0. The numbers are updated constantly during the door's opera-
tion and stand for the instantaneous torque reached by motor 1 (35) and torque
threshold (opening, closing, slow-down) set in the parameters menu (40).
Via these values, we can correct the torque setting.
If the value of the instantaneous torque reached during the door's operation gets
rather close to the threshold value set in the parameters menu, malfunctioning
may occur in the future due to wear or the door becoming slightly misshapen.
Consequently, it is advisable to check the maximum torque reached during a
INSTALLATION MANUAL
number of cycles at the installation stage and, where necessary, set a value ap-
prox. 5/10 percentage points higher in the parameters menu.
8.8) ERROR DIAGNOSTICS:
ER01
ER10
ER11
8.9) AUTOSET MENU
Move the door to the closed position
Launch an autoset operation by going to the relevant menu on the VENERE
D panel (Fig.B).
As soon as you press the OK button, the "........ .... " message is displayed and the
control unit commands the door to perform a full cycle (opening followed
by closing), during which the minimum torque value required for the door
to move is set automatically.
During this stage, it is important to avoid breaking the photocells' beams and
not to use the START and STOP commands or the display.
Once this operation is complete, the control unit will have automatically set
the optimum torque values. Check them and, where necessary, edit them as
described in the programming section.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
Warning!! While the autoset function is running, the obstacle detection
function is not active. Consequently, the installer must
8.10) LIMIT SWITCH ADJUSTMENT MENU
The VENERE D control panel has an opening and closing limit switch adjustment
menu, which simplifies the installation procedure.
Refer to Figures 18/19 and Fig.B illustrating the control panel's programming
and proceed as follows:
Launch a limit switch adjustment operation by going to the relevant menu
on the VENERE D panel (Fig.B).
When the "CLOSE" message is displayed, move the door to the desired closed
position using the "UP" and "DOWN" buttons on the control unit, bearing in
mind that the "DOWN" button closes the door, while the "UP" button opens
the door.
"OK" button to store the closed travel limit position.
When the "OPEN" message is displayed, move the door to the desired open
position using the "UP" and "DOWN" buttons on the control unit, bearing in
mind that the "DOWN" button closes the door, while the "UP" button opens
the door.
As soon as the door is in the desired open position, press the "OK" button to
store the open travel limit position.
Position the "runner stop" correctly up against the runner and secure in place
with the screws (fig.18 ref.6 A-B).
NOTE: These operations must be performed in "deadman" mode at reduced
speed and without the safety devices operating.
8.11) STATISTICS
Connect the UNIVERSAL HANDHELD programmer to the control unit, enter the
CONTROL UNIT/STATISTICS menu and run through the statistics parameters
screen:
-
Software version of card microprocessor.
-
Number of cycles performed. If the motors are replaced, write down the
number of operations performed so far.
-
Number of cycles performed since last service. Automatically reset every time
self-diagnosis is run or parameters are written.
-
Date of last service. Must be updated manually via the relevant "Update service
date" menu
.- System description. Allows for 16 characters to be entered to identify the
system.
9) TECHNICAL DATA OF BUILT-IN RECEIVER
Receiver's output channels:
-
output channel 1, if activated, commands the door to START
-
output channel 2, if activated, commands the 2nd radio channel relay to
energize for 1 sec..
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
9.1) INSTALLING THE ANTENNA
Use an antenna tuned to 433MHz.
Use RG58 coax cable to connect the Antenna and Receiver.
Metal bodies close to the antenna can interfere with radio reception. If the trans-
mitter's range is limited, move the antenna to a more suitable position.
9.2) RECEIVER SETUP
Cloning can only be performed with the relevant programmer (UNIRADIO).
The on-board receiver, which is of the cloneable kind, combines the qualities of
extreme security with rolling-code copying and the practicality of being able to
"clone" transmitters by virtue of an exclusive system.
Cloning a transmitter means generating a transmitter that can get itself entered
automatically on the list of transmitters memorized in the receiver either by being
added or by replacing a given transmitter.
Replacement cloning can be used to create a new transmitter that takes the
place of the previously memorized transmitter in the receiver. With this method,
a transmitter can be removed from the memory and be put out of service.
Hence a large number of added transmitters or transmitters replacing lost ones,
for example, can be programmed remotely without having physical access to
the receiver.
Error in safety device (photocell) test
Problems detected in motor's control circuit
Problems detected in motor's current reading circuit
As soon as the door is in the desired closed position, press the
ENGLISH
17
BOTTICELLI VENERE D -

Publicité

Table des Matières
loading

Table des Matières