MAINTENANCE

Replacing a Fuse

Use the following procedure to replace a damaged fuse(s).
1. move the Power ON/OFF (i/O) switch to the OFF (O)
position and unplug the power cord. allow the unit to cool.
2. Remove all components inside of the unit.
3. Remove the glass door(s) and side panel(s).
4. Carefully lay the unit on its side. Two people are required
for this step.

OPTIONS AND ACCESSORIES

Slant Leg Kit (GRHD Series)
a slant leg kit is available as an accessory for non-humidified
GRHD models. Slanted legs tilt the unit forward for optimum
display of food product. Use the following procedure to install
the slant leg kit.
1. Remove loose items inside of the unit.
2. Remove rear doors by sliding each door to the center then
lifting up and out of the bottom channel.
3. Carefully lay the unit on its side (requires two people).
4. Remove the screws from the bottom right and the bottom
left side of the unit.
5. Position the slant leg over the screw holes with the long
leg towards the rear, and install using original screws.
6. Return the unit to the upright position and adjust feet to
desired height. Feet have an adjustable range of 3/4"
(19 mm) to 1-1/2" (38 mm).
Display Sign Holder (GRHD Series)
Display sign holders are available accessories for the GRHD
series. Use the following procedure to install a display sign
holder to the unit.
1. Remove the screws from the upper left and right side of
the unit.
2. Position the sign holder over the screw holes and install
using the original screws.
3. insert sign (not included) and slide on the plexiglass cover.
Display Sign Holder (GRCD Series)
Display sign holders are available accessories for the GRCD
series. a display sign holder adds 8-1/4" (210 mm) to the height
of the unit. Use the following procedure to install a display sign
holder to the unit.
1. Remove the screws from the upper left and right side of
the unit.
2. Position the sign holder over the screw holes and install
using the original screws.
3. insert sign (not included) and slide on the plexiglass cover.
5. Remove the 4" (102 mm) legs from the bottom of the unit.
6. Remove all screws on the bottom panel of the unit and
remove the bottom panel.
7. Remove the damaged fuse(s) and replace with new
fuse(s).
8. Reverse the above procedure to reassemble.
Backlit Base Sign Holder (GRCD Series)
a backlit base sign holder is a factory installed option for the
GRCD series.
Mirrored Glass Doors
mirrored Glass Doors are available options for all GRHD and
GRCD models. a one way mirror enhances food displays on
the customer side while allowing the operator to review food
from rear.
Self Closing Flip-up Doors (GRCD Series)
Self closing flip-up doors are available as a factory installed
option for the front of GRCD dual series.
Front Sliding Door (GRHD Series)
a front sliding door is available as a factory installed option for
GRHD series only. a front sliding door allows access from the
operator and the customer side of the unit.
Flip-up Door (GRHD Series)
a flip-up door is available as a factory installed option for GRHD
series. a flip-up door allows access from the operator and the
customer side of the unit.
Sneeze Guard (GRHD Series)
a sneeze guard is available as a factory installed option for
GRHD series. a sneeze guard takes the place of sliding doors.
Pan Skirts
Various pan skirts are available for the GRHD and GRCD series.
Food Pans and Trivets
Stainless steel food holding pans are available in either 2-1/2"
(64 mm) or 4" (102 mm) depths. These pans are offered in full
size, half size, or third size. Optional wire trivets prevents food
from touching pan bottom.
Halogen Display Light Bulbs
Shatter-resistant halogen display light bulbs
can be ordered in place of the standard
incandescent display light bulbs. The bulbs
have a special coating to guard against injury
and food contamination in the event of
breakage. For 120, 120/208, and 120/240 volt
applications, use Hatco P/N 02.30.081.00.
16