Sensitivity: Low Voltage; Sensitivity: High Voltage - Amprobe TIC 300 PRO Mode D'emploi

Détecteur de tensions alternatives sans contact
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Sensitivity: LOW Voltage

Hold the TIC 300 PRO when making the detection range
measurement for LOW voltage range.
Voltage
(Phase to neutral with
890K Ohm load)
100 V
120 V
220 V
500 V
1000 V

Sensitivity: HIGH Voltage

The TIC 410A Hot Stick must be used when making
detection range measurement for HIGH voltage range.
Voltage
(Open Phase with no load)
1.5 kV
2.0 kV
4.0 kV
10.0 kV
15.0 kV
20.0 kV
25.0 kV
30 V
75 V
Detection Range
(From the TIP of probe to
the target line)
Average
3.8 cm (1.5 in)
16.5 cm (6.5 in)
21.6 cm (8.5 in)
25.4 cm (10 in)
33 cm (1 ft 1 in)
48.3 cm (1 ft 7 in)
86.4 cm (2 ft 10 in)
Detection Range
(From the TIP of probe to
the target line)
Average
12.7 mm (0.5 in)
25.4 mm (1 in)
5.1 cm (2 in)
20.3 cm (8 in)
35.6 cm (1 ft 2 in)
50.8 cm (1 ft 8 in)
66 cm (2 ft 2 in)
11