Anselmo Cola TERMO PLUS 29 Manuel D'installation, D'utilisation Et D'entretien page 57

Publicité

Les langues disponibles
  • FR

Les langues disponibles

-Occurs in case of water T
Al G
detection probe fault,
WATER
displaying T H2O = 0 °C.
- The shutdown procedure
PROBE S2
is activated.
-Occurs when the water
AL I
temperature has exceeded the
HOT
fixed limits.
WATER S2
-The system is stopped.
-Occurs in case of water T
Al H
detection probe fault,
WATER
displaying T H2O = 0 °C.
- The shutdown procedure
PROBE S3
is activated.
-Occurs when the water
AL d
temperature has exceeded the
HOT
fixed limits.
WATER S3
-The system is stopped.
-Occurs on relighting the stove
AWAITING
immediately after having shut
COOL
it down.
AIRFLOW
-Occurs when the air flow
METER
meter is disconnected.
FAILURE
-Occurs when the water
FROST RISK
temperature falls below a
certain value.
-Occurs when the stove has
exceeded 1800 hours of
SERVICE
operation or 2000 Kg pellet,
DUE
since the previous servicing.
-Faulty probe
-The probe is disconnected
from the board.
-Occurs when the temperature
probe in the heating chamber
detects a value above 92°C.
-Faulty probe
-The probe is disconnected
from the board.
-Occurs when the temperature
probe in the heating chamber
detects a value above 92°C.
-Reset attempt in shutdown
stage with stove hot in cooling
stage.
-The controller does not detect
the amount of combustion air
and does not shut down the
stove; it only excludes the air
flow meter functions.
-The stove controller detects
the water temperature below
6°C and displays a message.
-Extraordinary
maintenance
notice.
57
-Reinstatement operations
must be carried out by a
service centre.
-Check the cause of the
problem, restoring the
temperature by bringing it to
the normal operating value.
-Reinstatement operations
must be carried out by a
service centre.
-Check the cause of the
problem, restoring the
temperature by bringing it to
the normal operating value.
-Alarm reset is possible only
after shutdown.
-Reinstatement operations
must be carried out by a
service centre.
-The pump starts in order to
move the water inside the
heating circuit.
- Monitor the water
temperature so that it does not
fall below 0°C.
- Cleaning - extraordinary
maintenance and
reinstatement operations must
be carried out by an
authorised service centre.
TERMOPLUS 29