4.3.2 Startup stage
To light the stove, press the button 'P4' for 3 seconds: the message 'START' will appear on the display.
This stage is automatic and managed entirely by the electronic controller without the possibility of changing the
parameters. Alternatively the stove can be lit by pressing the buttons P4 and P5 together for 3 seconds. The
message AWAITING REQUEST appears on the display. With this mode the stove switches to standby status and
carries out the lighting-start stage only if a request for heat is recognised, e.g. to heat the water or for DHW (if
available).
Dialogue box
The stove carries out the startup stages in
sequence according to the procedures defined by
the parameters that manage levels and times,
reaching the work condition unless anomalies or
alarms occur, according to the following table:
After a certain time has elapsed, if the fume
temperature has not reached the permissible
minimum value the stove goes in alarm status.
- Do not use flammable liquids to light the unit.
- In case of persistent failed lighting, contact the Service Centre.
4.4 Work stage
After the 'STARTUP' stage, the stove goes to the 'WORK' mode which is the normal operation mode.
The user can adjust the heating power from the max. value of 5 to a min. of 1 with the buttons 'P5' and 'P6'.
DHW circuit function activation ON is displayed by the segment/LED [A].
Storage tank -Puffer
H20 temperature or
'ROOM' word
Dialogue box
Power set to
- Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of pellets.
- Make sure the unit is off when loading pellets.
- The pellet hopper lid must always remain closed; it must only be opened when loading fuel.
- The bags of pellets must be kept at least 1.5 m from the stove.
Clock
Storage tank-Puffer H
Water temperature
Clock
3
0 temperature
2
Button 'P4'
Status
OFF
START - PREHEAT
PELLET PRELOAD
AWAITING FLAME
PELLET LOADING
FIRE PRESENT
WORK
WORK MODULATE
BRAZIER CLEANING
WORK
FINAL CLEANING
A
Button 'P6'
Button 'P5'
Water temperature or room temperature
Real power in work equal to 1 - flashing
47
Devices
Fume
igniter
auger
extr.
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF