4.6.1 Menu 01 – Chrono setting
Allows all chronothermostat functions to be enabled/disabled;
select ON to activate the function and display the relevant
segment/LED [ D ]
When Daily, Weekly or Week End programming is entered, the
appropriate segment/LED [ C ] appears in the top right of the display.
Regarding selections and entering times,
use the buttons according to the table in par. 4.2.
By accessing the submenu: DAY PROGRAM, the daily
chronothermostat functions can be enabled/disabled and set.
It is possible to set two operation stages delimited by the
times set according to the following table where the setting
OFF tells the clock to ignore the command.
Selection
Meaning
START1
activation time
STOP1
deactivation time
START2
activation time
STOP2
deactivation time
By accessing the submenu: WEEK PROGRAM it is possible to
enable/disable and set the weekly chronothermostat functions.
The weekly programmer has 4 independent programs whose final
effect consists of a combination of the
4 programmings.
The weekly programmer can be activated or deactivated;
also, by setting OFF in the time field, the clock ignores the
corresponding command.
Carry out programming making sure not to overlap the hours of
activation and/or deactivation on the same day in different programs.
By accessing the submenu: WEEK-END PROGRAM it is possible to
enable/disable
and
set
chronothermostat functions.
Activate WEEK-END programming only after deactivating the weekly
programming.
To avoid unwanted startup and shutdown operations, only activate
one program at a time.
Deactivate the daily program if the weekly program is required; with
this setting it is advisable to deactivate the week-end program.
4.6.2 Menu 02 – User adjustments
With this menu it is possible to do a number of settings as follows
- Set clock
Before operating with the stove, it is necessary to set the current time and date so that there is a reference for
possible chrono programming. The electronic controller has a lithium battery, model CR2032 3 Volt, giving the
internal clock an autonomy of more than 4-5 years; with the stove off, whenever the clock does not keep the time, or
a series of zeros is displayed at restart, the battery must be replaced by calling an authorised service centre.
- Standby mode
En mettant le mode VEILLE sur ON, le symbole correspondant s'allume sur l'afficheur et le poêle s'éteint
automatiquement dès que la température ambiante atteint la valeur du POINT DE CONSIGNE (Tset+∆T) pendant
une durée donnée. Il se remettra en marche automatiquement dès que la température ambiante sera redescendue
de quelques degrés sous la valeur programmée _ Tset-∆T (avec ∆T=2 °C par défaut).
Si le mode VEILLE est sur OFF, il n'est pas validé et le poêle fonctionne en mode modulation. Par conséquent,
lorsque la température dépasse la valeur du POINT DE CONSIGNE, le poêle fournira la puissance minimum.
- Initial load
Setting this function allows activation of gearmotor operation, with the stove off or cold, for pellet preloading of 90
sec. It starts with button P1 and stops with button P4.
Possible Values
time - OFF
time - OFF
time - OFF
time - OFF
the
week-end
(Saturday
-
Sunday)
51
C
D
Menu level
Input
Menu level
SOLAR PLUS 23